Mounting the Lens
| @Cmountiens || 1) 9 mm (%s inch) or less
@® CS mount lens
| 2) 4mm (°/s2 inch) or less
* Be sure to attach the lens mount cap when the lens is not mounted.
* Only lenses that are suitable for a 1/3type CCD should be used with
this camera. If lenses for a 2/3type or 1/2type CCD are used, the view
angle will be different.
= 3 Da
The camera is supplied with a plug for inserting into the LENS connec-
tor on the side of the camera. When fitting a DC servo auto-iris lens,
you will need to replace the plug on the lens cabie with the plug
supplied. Replace as follows:
@ Cover
@ Lens cable
© Rib (/f the cable is thick and the plug cover does not seat properly,
cut away this rib.)
© Lens plug
1 Remove the plug cover and solder the lens cable wires to the pins
on the plug supplied. The pin assignment is as follows:
>
Nn
Drive (-) (Ground)
od oa
3.1
2 Put the cover on the plug.
When using a DC servo auto-iris lens, fit it as follows. For a manual-iris
lens, omit step 3.
1 Unscrew lens mount cap.
2 Screw in the lens.
3 First, replace the plug on the lens cable with the plug supplied with
the camera. Then, connect the camera cabie piug to the LENS
socket.
4 Loosen the back focus LOCK screw. Adjust the back focus by
turning the C/CS adjustment ring in accordance with the type of lens
fitted (C-mount or CS-mount). Once adjusted, tighten the back focus
LOCK screw. (The factory setting is CS-mount.)
When attaching a C-mount type lens, be sure to turn the C/CS
adjustment ring fully in the "C" direction. When the C/CS adjustment
ring is set to "CS," mounting any lens with a mount projection of more
than 4 mm may damage the internal parts of the camera.
Connections
1 Connect the power lines to the camera.
2 Connect the 75-ohm coaxial cable to the video monitor.
3 Connect the wall outlet transformer.
* When using a transformer without a ground lead (two-lead type),
connect the output of the transformer to the AC 24V 1 and 2 terminals
of the camera.
* When using a transformer with a ground lead (three-lead type),
connect the ground lead to the GND terminal and the other two leads
to the AC 24V 1 and 2 terminals.
¢ To prevent a short circuit, do not let the exposed transformer leads
brush against conductive material when connecting to the AC 24V
terminals.