4
Maintenance
4.1
Maintenance Table
The following details are manufacturer recommendations. Observe national
guidelines, too.
Work to be carried out
Inspection by wearer of device
Cleaning and Disinfection
Visual inspection, function and leak tests
Replacing the exhalation valve disc
Replacing the speech diaphragm
Replacing the O-ring of the speech diaphragm
1)
full facepieces in airtight packaging, otherwise every six months.
2)
full facepieces in airtight packaging every 2 years.
4.2
Cleaning and disinfecting
4.2.1
Cleaning and disinfecting
The facepiece must be cleaned after every use so that it is clean before it is
used by a different individual or, if individually assigned, as often as necessary
to keep in a sanitary condition. Facepieces that are issued to more than one
user must be cleaned before being worn by different individuals.
Instructions for use
|
Dräger X-plore 5500 Use Instructions for NIOSH-approved full facepieces
The facepiece must be disinfected after every use to keep it in a sanitary
condition. It is fully in the user's responsibility to make sure that the facepiece is
totally free of contaminants after this treatment. Never use a facepiece again,
that has not been properly disinfected. In case of doubts dispose of the
facepiece in accordance with the local regulations and use a new one.
Maximum intervals
The facepiece body must be cleaned thoroughly so that no residues from skin
care products remain on it. Otherwise the elasticity in the sealing area can be
lost and the facepiece will no longer fit correctly.
Failure to take note of this warning can result in poisoning or death.
Do not use any solvents (e.g. acetone, alcohol) or cleaning agents containing
abrasive particles for cleaning and disinfecting. Only apply the described
procedures and use the cleaning and disinfecting agents given. Other agents,
X
dosages and exposure times may damage the product.
NOTICE
X
1)
X
Since the use of certain cleaning and disinfecting agents is not allowed among
X
2)
X
all countries, Dräger tested and recommends several cleaning and disinfecting
agents. However, Dräger makes no representations that such agents comply
X
with or are approved for use in your specific country's regulations. Make sure to
follow the procedure that is suitable for your country.For further information
X
please contact Dräger or your local dealer.
X
4.2.2
1. Remove any accessories from the facepiece and clean them separately
2. Prepare a cleaning solution consisting of water and a cleaning agent.
3. Clean all parts using a soft cloth with cleaning solution.
4. Rinse all parts thoroughly under running water.
5. Prepare a disinfecting solution consisting of water and a disinfecting agent.
6. Place all parts that need to be disinfected into the disinfectant bath.
1)
WARNING
CAUTION
For information about suitable cleaning and disinfecting agents and
their specifications refer to document 9100081 at
www.draeger.com/IFU.
Cleaning and disinfecting procedure
Strictly follow the corresponding Instructions for Use.
Maintenance
1)
.
69