Air volume table
000 gear (default)
Model
air volume(CFM)
660
18K
10KW
880
24K
15KW
1100
30K
15KW
1320
36K
20KW
1760
48K
20KW
2195
60K
25KW
NOTE
The wind gear DIP switch can only change the air volume when the electric heating is turned on,
and the unit cooling and heating air volume remains unchanged. If the DIP switch is wrong, the
default wind gear will be run.
24V control DIP switch:
DH
R
C
L
G
Y1
INDOOR UNIT
S4-1 DIP switch o
Perform disconnection and
short-circuit to achieve
partition, control or
dehumidi cation
001 air volume(CFM)
630
10KW 、8KW
850
15KW 、8KW
1040
15KW 、10KW
1255
15KW
1675
15KW 、10KW
2055
20KW 、15KW
B W
W1 W2
E
S4-2 DIP switch o
Disconnect and short
circuit to realize heating
segment
Page 50
010 air volume(CFM)
600
8KW
830
10KW、8KW
990
10KW、8KW
1190
10KW、8KW
1580
10KW、8KW
1920
15KW、10KW
011 air volume(CFM)
570
5KW、3KW
800
5KW、3KW
930
8KW、5KW
1125
8KW、5KW
1490
8KW
1775
10KW