Transport
A lift truck is suited for transporting the unit on a level surface.
Carrying straps may be used if the heat pump needs to be
transported on an uneven surface or carried up or down stairs.
These straps can be passed directly underneath the pallet.
CAUTION!
The heat pump is not fixed to the pallet.
CAUTION!
The heat pump must not be tilted more than 45° (in any
direction).
Use the holes provided in the sides of the frame to lift the unit
without the pallet. The side panel assemblies must be removed
for this purpose. Any commercially available length of pipe can
be used as a carrying aid.
CAUTION!
Do not use the holes in the panel assemblies for lifting the
device!
After the transport, the transport securing device is to be re-
moved.
1.
2.
CAUTION!
The transport securing device is to be removed prior to
commissioning.
EN-4
Remove
transport lock
452235.66.21a · FD 0106
6
Set-up
6.1 General Information
The compact water-to-water heat pump must be installed in a
frost-free, dry room on an even, smooth and horizontal surface.
The entire base of the frame should lie directly on the floor to
ensure an adequate soundproof seal. If supporting feet are
used, the heat pump must be installed horizontally. In this case,
the specified sound level can be up to
3 dB(A) higher, and additional sound insulation measures may
be necessary.
The heat pump must be installed so that maintenance work can
be carried out without hindrance. This can be ensured by main-
taining a clearance of approx. 1 m in front of and on each side
of the heat pump.
Neither frost nor temperatures higher than 35 °C must occur in
the installation location at any time of the year.
6.2 Acoustic Emissions
The heat pump operates silently due to efficient sound insula-
tion. Internal insulation measures should be carried out to pre-
vent vibrations from being transmitted to the foundation or to
the heating system.
7
Installation
7.1 General Information
The following connections need to be established on the heat
pump:
Flow and return flow of the well system
Flow and return flow of the heating system
Temperature sensor
Voltage supply
WI 10TU - WI 22TU
www.glendimplex.de