Télécharger Imprimer la page

Wieland SNH Serie Mode D'emploi page 27

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
Actuating elements for emergency stop M12
Function according to EN 418 /
EN ISO 13850
Emergency stop heads
Housing material
Unlocking
Protection rating
Rated impulse withstand voltage U
Ambient operating temperature
Storage temperature
Torque
Installation diameter
Short-circuit protective device
Contact blocks
Contact type
Contact material
Mechanical life
Electrical life cycle
Utility category
Thermal continuous current Ith
Continuity resistor
Bounce time
Connection system
Number of poles
Approvals
Rated short-circuit current
Additional Data
Pollution degree
Safety-relevant characteristics
B
10D
Ui = Rated insulation voltage; Ue = Rated operating voltage; Ie = Rated operation current
Doc. # BA000612 – 05/2023 (Rev. E)
SNH 1102 M12
Emergency stop
Plastic (PA)
Rotary release left/right
IP65/IP67 (from the front side) IP65/IP67 (from
the rear side, with a connected M12 connector)
2.5 kV (contact block)
imp
-25°C ... + 70°C
-40°C ... + 80°C
1.0 Nm ... 1.7 Nm
22.3 mm
Fuse cutout 2A gG
2 positive opening contacts
AgNi
50,000 switching cycles
50,000 switching cycles
AC15
50 V (Ui), 35 V (Ue) 2 A (Ie)
DC13
50 V (Ui), 35 V (Ue) 2 A (Ie)
2 A
< 50 mΩ
< 10 ms
M12 connector (A-coded)
5
CE, TÜV, c(UR)us, UKCA
1000 A
2
226,000
SNH
EN 27 / 99

Publicité

loading

Ce manuel est également adapté pour:

Snh 00 serieSnh 11 serieSnh 1102 m12Snh 2402 m12