Télécharger Imprimer la page

Ryobi RY18CB23A Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
European Conformity Mark
EurAsian Conformity Mark
Ukraine Conformity Mark
Do not dispose of waste
batteries, waste electrical
and electronic equipment as
unsorted municipal waste.
Waste batteries and waste
electrical and electronic
equipment must be collected
separately. Waste batteries,
waste accumulators, and light
sources have to be removed
from the equipment. Check with
your local authority or retailer for
recycling advice and collection
point. According to local
regulations, retailers may have
an obligation to take back waste
batteries and waste electrical
and electronic equipment free
of charge. Your contribution to
the reuse and recycling of waste
batteries and waste electrical
and electronic equipment helps
to reduce the demand of raw
materials. Waste batteries, in
particular containing lithium, and
waste electrical and electronic
equipment contain valuable
and recyclable materials, which
can adversely impact the
environment and the human
health if not disposed of in an
environmentally compatible
manner. Delete personal data
from waste equipment, if any.
SYMBOLS IN THIS MANUAL
Parts or accessories sold
separately
Note
Warning
USING THE E-MODES
The E-modes are advanced settings that are
recommended when operating the product
in certain situations only. The manufacturer
recommends using the provided factory
settings.
Mode
Function
Lowest
E1
temperature
Highest
E2
temperature
Temperature
E3
return
E4
Soft start
Fahrenheit and
E5
Celsius
Temperature
E6
compensation for
≥ 7 °C
Temperature
E7
compensation for
7 to -12 °C
Temperature
E8
compensation for
≤ -13 °C
E9
Undercooling
In E3 mode, if the temperature is set to -20
°C, the compressor stops running until the
temperature reaches -17 °C.
In E4 mode, if the product is connected to a 12
V power supply, the compressor starts working
after 2 minutes to protect the vehicle battery.
In E6, E7, and E8 modes, the temperature
displayed on the control panel is the
combination of the ambient temperature
detected and the temperature compensation.
In E9 mode, the factory setting is not adjustable.
NOTE: To reset the product to its factory
settings, see the Using the Control Panel
section in this manual.
Factory
Setting
setting
range
-20 °C
Up to -40 °C
+20 °C
Up to +40 °C
3 °C
1 to 10 °C
2 mins
0 to 10 mins
°C
°F or °C
-10 °C to
0 °C
+10 °C
-10 °C to
0 °C
+10 °C
-10 °C to
0 °C
+10 °C
0 °C
-
7
Original Instructions
EN
FR
DE
ES
IT
NL
PT
DA
SV
FI
NO
RU
PL
CS
HU
RO
LV
LT
ET
HR
SL
SK
BG
UK
TR
EL

Publicité

loading