Rotary Switch Positions; Hold Button - Amprobe AM-420 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Rotary Switch Positions

Switch Position Measurement Unit
250
{
200
250
200
|
20
2
200m
20m
[
2m
200μ
2M
200k
e
20k
2k
200
9V
1.5V
G

HOLD Button

Press HOLD button to freeze present reading on display. Press again to resume
normal operation.
X�
Warning
To avoid electric shock, do not use the HOLD mode to determine if a circuit is
live. The meter holds the reading on the display and does not refresh the reading
automatically.
The "HOLD" button may be activated even when the product is NOT on. (If
"H" appears in the left-side of the display, HOLD is active.) The HOLD function
allows the meter to continue displaying the last reading, which may be "0". This
reading will not change as long as the HOLD function is active, even if the meter
is later connected to an energized circuit. "HOLD" can be disabled by pressing the
"HOLD" button again. Readings will resume.
V AC
V AC
V AC
V DC
V DC
V DC
mA DC
DC current measurement up to 200 mA
mA DC
mA DC
μA DC
DC current measurement up to 200 μA
Ω
For measurement of dry batteries of not
V DC
For measurement of dry batteries of not
V DC
V DC
Voltage measurement of diode PN junction
Ω
5
Measurement Function
AC voltage measurement up to 250 V
AC voltage measurement up to 200 V
DC voltage measurement up to 250 V
DC voltage measurement up to 200 V
DC voltage measurement up to 200 V
DC voltage measurement up to 2 V
DC current measurement up to 20 mA
DC current measurement up to 2 mA
Resistance measurement up to 2 MΩ
Resistance measurement up to 200 kΩ
Resistance measurement up to 20 kΩ
Resistance measurement up to 2 kΩ
Resistance measurement up to 200 Ω
exceeding 15 Vdc
exceeding 2 Vdc
Continuity measurement, buzzer will
sound when ≤ 10 Ω

Publicité

Table des Matières
loading

Table des Matières