3CS = Three Compartment Sink
Plug Configurations
Some units are supplied from the factory with an electrical
cord and plug installed. Plugs are supplied according to the
applications.
WARNING
ELECTRIC SHOCK HAZARD: For units with an electrical
cord and plug, plug unit into a properly grounded
electrical receptacle of the correct voltage, size, and plug
configuration. If plug and receptacle do not match, contact
a qualified electrician to determine and install proper
voltage and size electrical receptacle.
Electrical Rating Chart—3CS2 Models
Model
Voltage
3CS2-3
208 V
3CS2-4
208 V
240 V
3CS2-6
208 V
3CS2-3B
208 V
240 V
3CS2-4B
208 V
240 V
3CS2-6B
208 V
240 V
3CS2-9B
208 V
* Wire size is based on THHN copper wire for branch circuit protection at 0.91 derate factor. Circuit breakers and fused disconnects
are to be mounted remotely and wired by contractor. Sizes are based on the 2002 NEC table 310-16. Conduit size based on
conductors plus ground wire sizing per Table C1 from Appendix C.
† Based upon THHN wire rated 90ºC.
NOTE: Shipping Weight includes packaging.
HHM-0224
FR = Food Rethermalizer/
Bain-Marie Heater
Hydro-Heater
Kilowatts
Phase
3.0 kW
1
4.0 kW
1
6.0 kW
1
3.0 kW
3 (Bal.)
4.5 kW
3 (Bal.)
6.0 kW
3 (Bal.)
9.0 kW
3 (Bal.)
3 C S 2 - x B
NEMA 6-20P
(Available for FR2-3 only)
NOTE: The specification label is located on the front of the
unit. See label for serial number and verification of unit
electrical information.
Wiring Sizing
Amps
AWG*†
14.4 A
12
19.2 A
10
16.7 A
28.8 A
8
8.4 A
14
7.3 A
11.2 A
14
9.6 A
16.7 A
12
14.5 A
25 A
10
5
MODEL DESIGNATION
Balanced—3 Phase
Kilowatt Rating
SPECIFICATIONS
NEMA 6-30P
(Available for FR-4 only)
Plug Configurations
Fuse or
Circuit Breaker* Shipping Weight
20 A
24 lbs. (11 kg)
30 A
24 lbs. (11 kg)
40 A
27 lbs. (12 kg)
15 A
24 lbs. (11 kg)
20 A
24 lbs. (11 kg)
15 A
30 A
27 lbs. (12 kg)
20 A
40 A
27 lbs. (12 kg)