OPTIONS AND ACCESSORIES
Remote Mounted Control
A remote mounted control is available for 3CS2 and FR2
models. The remote mounted control is shipped with a 45"
(1143 mm) remote control cord and a remote plug cover.
Installing the Remote Mounted Control
To install the remote mounted control:
1. Cut a hole 3" (77 mm) wide and 1-1/4" (32 mm) high in the
vertical mounting surface.
2. Feed the remote control cord through the
3. Push the remote mounted control into the cutout until it
snaps in place.
NOTE: If the cutout hole is too small, cut the hole to the
appropriate size until the remote mounted control slides
into the cutout hole and snaps into place.
Installing the Remote Plug Cover
1. Plug the remote plug into the remote receptacle on the
unit.
2. Position the remote control cord into the slot on the remote
plug cover, and install the cover over the remote plug on
the unit. Secure in position using the acorn nuts.
3. Place the included bushing on the remote control cord
above the slot on the remote plug cover.
4. Push the bushing down into the slot on the remote plug
cover.
To Remote
Mounted
Control
Receptacle
Slot
Remote
Bushing
Plug
Cover
Acorn
Remote
Nut
Control Cord
Installing the Remote Control Plug Cover
Changing the Setpoint Temperature
To set the remote mounted control to the desired setpoint
temperature:
1. Touch the set key. The display will show "SP1".
2. Touch the set key again. The display will show the current
setpoint temperature.
3. Touch the up arrow or down arrow to adjust the setpoint
temperature. The display will show the new setpoint
temperature.
4. Touch the set key when the desired setpoint temperature
is shown. The display will go blank.
• Wait 5 seconds and the unit will show the current
operating temperature.
NOTE: If step 3 is interrupted or no changes are made for 15
seconds, the controller will go back to its original setting
without accepting the change.
cutout.
Remote
Remote
Plug
Remote Mounted Control
Flush Hose Kit
The Flush Hose Kit is available for 3CS2 and FR2 models and is
used to power flush the unit to keep it working at peak efficiency.
The kit consists of a drain stopper, cleaning brush, and adapter.
Use the following procedure to power flush the unit.
1. Move the Power I/O (on/off) switch to the O (off) position
and allow the unit and water to cool.
2. Connect one end of a drain hose onto the drain outlet and
place the open end in a bucket or open site drain in a
manner according to local plumbing codes.
3. Drain the sink or holding vessel by moving the drain handle
backwards until it is completely horizontal. Water will now
flow from the drain hose.
4. Place the rubber stopper into the inlet strainer.
NOTE: The inlet strainer is the strainer closest to the front of
the unit.
5. Attach the flush hose with adapter to a fresh water supply,
and place hose into outlet strainer. Flush fresh water
through the unit until the discharge from the drain is clear.
6. Turn off the fresh water supply, and reverse the positions of
the rubber stopper and the power flush hose. Flush fresh
water through the unit again until discharge from the drain
is clear.
7. Turn off the water supply, remove the rubber stopper and
power flush hose, and allow the unit to finish draining.
8. Remove clean-out caps and insert cleaning brush into
clean-out and drain outlets. Use a scrubbing motion to
clean the chambers
9. Reinstall the clean-out caps.
10. Rinse fresh water through the unit until discharge is clear.
11. Close drain by moving the drain handle all of the way
forward until it is completely vertical.
NOTE: Perform the entire "Daily Cleaning" procedure in the
MAINTENANCE section of this manual if buildup is
significant.
14