4 Technical data
4.7
Environmental influences
Admissible ambient temperature
With CO
module
2
With display
Admissible storage temperature
With CO
module
2
With display
Protection type
Max. site altitude
Climatic conditions
Climate class
Relative humidity
Electromagnetic compatibility
(EMC)
Interference emission
Interference immunity
b
Oscillation
Amplitude
Acceleration
b
Shock
Peak acceleration
Shock duration
a
The product is suitable for industrial use as well as for households and small businesses.
b
The CO
module is sensitive to vibrations. In the event of vibrations, the measurement results could change on
2
account of the design.
4.8
Mechanical features
Materials
Housing
Display cover
Weight
12
-40 to +80 °C
-10 to +60 °C
-20 to +60 °C
-40 to +80 °C
-30 to +70 °C
-30 to +60 °C
DIN EN 60529
IP65
5,300 m above sea level
DIN EN IEC 60721-3-3
3K24
≤ 100 % (95 % with CO
DIN EN IEC 61326-2-3:2022
a
Class B
Industrial requirement
DIN EN 60068-2-6
0.15 mm at 10 to 58.1 Hz
2
20 m/s
at 58.1 to 150 Hz
DIN EN 60068-2-27
2
150 m/s
11 ms
PC
PMMA
Approx. 260 g
module), non-condensing
2