2 - TECHNICAL DATA – DATA PLATE
Power supply
(voltages range)
Welding process
Power supply at:
ED 60%
ED 100%
Primary consumption at I
max.
2
Effective consumption
Open circuit voltage
Welding current
Duty cycle
at 35%
10 min. cycle (40°C)
at 60%
at 100%
Electrode diameters (MMA)
Weldable electrodes
Protection / insulation class
VRD function
TIG LIFT start
Electrode diameters (TIG)
Dimensions (W x H x L) / Weight
Standards
The machine can be connected to a motor generator of power meeting the data plate specifications above.
NOTE: THIS POWER SOURCE CANNOT BE USED IN FALLING RAIN OR SNOW. IT MAY BE STORED OUTSIDE, BUT IT IS NOT DESIGNED FOR
USE WITHOUT PROTECTION DURING PRECIPITATION.
Code letter
First digit
Second digit
IMPORTANT: MAKE SURE THE POWER SOURCE MEETS THE ABOVE REQUISITES. EXCEEDING THE SPECIFIED VOLTAGES CAN DAMAGE THE
WELDING MACHINE AND INVALIDATE THE WARRANTY.
2.1 - ACCESSORIES
Consult the area agents or the dealer.
2.2 - DUTY CYCLE AND OVERHEATING
Duty cycle is the percentage of 10 minutes at 40 °C ambient temperature
that the unit can weld at its rated output without overheating. If the unit
overheats, the output stops and the over temperature light comes ON. To
correct the situation, wait the unit to cool. Reduce amperage, voltage or duty
cycle before starting to weld again.
TECHNICAL DATA – DATA PLATE
PRESTO 300MV FLEX LINE
230 V AC – 1 ph – 50/60 Hz
(from 180 V AC to 265 V AC)
TIG
MMA
3,3 kVA
4,5 kVA
2,5 kVA
3,4 kVA
23,5 A
27,0 A
16 A
14 V 81,5 V (14 V VRD)
5 – 215A
5 – 180A
215 A (30%)
180 A
150 A
135 A
120 A
105 A
1,6 to 4,0 mm
TIG: ON ---- MMA: ON or OFF (see Ref.12 - section 6.1)
1,0 to 2,4 mm
IP
2
Against penetration of solid foreign bodies with ∅ ≥ 12,5 mm
1
Against penetration of vertical drops of water with harmful effects
2
Against penetration of rain (inclined up to 15° in relation to the vertical) with harmful effects
3
Against penetration of rain (inclined up to 60° in relation to the vertical) with harmful effects
S
Indicates that testing for protection against the undesirable effects of water penetration
230 V AC – 3 ph – 50/60 Hz
(from 180 V AC to 265 V AC)
TIG
MMA
5,5k VA
6,2 kVA
4,1 kVA
4,6 kVA
19,3 A
21 A
13 A
14 V 81,5 V (14 V VRD)
5 – 270A
5 – 215A
270 A (40%)
215 A (40%)
215 A
175 A
170 A
135 A
1,6 to 5,0 mm
E6010 - E6011 – E6013 – E7018
IP22S / H
ON
1,0 to 2,4 mm
220 x 394 x 534 mm / 22 kg
EN 60974-1; EN 60974-10
Degrees of protection
was carried out with all parts of the equipment at idle.
EN-5
EN
400 V AC – 3 ph – 50/60 Hz
(from 340 V AC to 440 V AC)
TIG
MMA
5,8 kVA
8,3 kVA
4,0 kVA
6,5 kVA
11,4 A
16,5 A
10 A
14 V
81,5 V (14 V VRD)
5 – 270A
5 – 270A
270 A
270 A
205 A
205 A
160 A
160 A
1,6 to 6,3 mm
1,0 to 3,2 mm

Publicité

loading