E. Suction side view
A
B
C
D
A
Top panel can be dismantled via 4 screws
B
Side panel can be dismantled
C
Condensate drip tray + draining pipe
D
Air intake panel can be dismantled via magnets
2. Important safety
recommendations
!
This product contains hermetically-sealed
flammable R290 gas.
READ THE MANUAL CAREFULLY BEFORE
USING THE APPLIANCE and retain it for future
reference
When using your conditioner, always observe certain basic
precautions, notably:
Only use the conditioner for the purpose for which it was intended,
as described in this guide.
Never unplug the appliance by pulling the power lead. Hold the
lead's plug firmly and pull straight out to remove it from the wall
socket. If the power lead is damaged, it must be replaced by a
qualified electrician.
Do not let children climb, sit, stand or hang from the conditioner.
They could damage the conditioner and seriously injure themselves.
This appliance is not designed to be used by people (including
children) with reduced mental, sensory or physical abilities, or
by people lacking experience and knowledge, unless they are
supervised or given instructions on how to use the appliance by a
person responsible for their safety. Children must be supervised to
ensure that they do not play with the appliance.
Product exclusively designed for wine cellars or rooms which are not
lived in (storeroom, garage).
8
E
Side panel can be dismantled
F
Grey=Pump Supply
G
Pink=0-10 Fan
H
Location of cellar sensor on front
!
Never damage your appliance's refrigerating circuit.
Incorrect use or installation can cause injury to individuals, damage
to property and invalidate the manufacturer's warranty. Failure to
observe safety recommendations and local standards in force
during use or installation shall release the manufacturer from all
responsibility.
• Ensure that you install the appliance in a place protected from bad
weather and frost.
• This appliance contains refrigerant gas R290 – ensure that you
install it in a sufficiently ventilated room (see loading refrigerant in
the data sheet).
• The equipment must be installed in a room without a permanent
source of ignition, such as, for example, a naked flame, fuel
burning appliance, electric radiator etc.
• Stagnation of any leaks of refrigerant gas in non-ventilated rooms
can result in a fire or explosion risk if the refrigerant comes into
contact with a source of ignition.
• Be aware that some refrigerant gases are odourless.
• Any intervention on a refrigerating circuit must be carried out by
a professional approved by an accredited body certifying their
competency to handle refrigerants.
• The appliance must be free from obstruction at all times to ensure
that it operates correctly and to reduce safety risks.
E
F
G
H