MAINTENANCE AND STORAGE
1. Inspect your heater before each use. Check all connections for leaks, following the procedure outlined on
Pages 4 and 5. Check the Regulator Hose (dual burner models only) for any cracks, breaks or wear. If the
hose is damaged replace it with the correct manufacturers part.
2. After use, always disconnect the heater from the LP cylinder, and store the heater separately from the tank.
Be sure to close the tank valve after use, and before storage. The LP cylinder should be stored outdoors
in accordance with chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gasses
(ANSI/INFPA 58).
3. Remove thermocouple retaining bracket screw from back of burner assembly. Remove bracket.
4.
Note position of thermocouple in retaining tabs on the back of the Burner assembly. Remove the thermocouple.
5. Remove wing bolt and fiber washer that attached the safety shut-off to the burner Assembly.
6. Slide the safety shut-off from burner assembly.
7. Remove burner orifice from the safety shut-off.
8. Clean burner orifice with compressed air (80 psi max).
9. Direct compressed are through the burner venturi tube toward the burner plenum so that dust collected
on the grid screen will be blown outward. Keep face away from the grid screen.
10. Reassemble heater in reverse order of disassembly.
CAUTION: ALWAYS KEEP THIS HEATER OUT OF THE REACH OF CHILDREN.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
Propane Tank Top Heaters Manual
MAINTENANCE
15