Télécharger Imprimer la page

Mi-T-M Corporation MH-0015-IM11 Manuel De L'opérateur page 11

Publicité

Les langues disponibles

Les langues disponibles

14. NEVER handle an operating or hot heater, as severe burns may result. Wing nuts and burner heads become
very hot during operation. Do not attempt to adjust burner position while heater is operating. Always allow
at least 15 minutes of cooling time before handling the heater.
15. This heater is shipped from the factory for use with LP (propane) gas only. Do not convert to any other
gas. Installation must conform to local codes, or in their absence, with the standard for the Storage and
Handling of Liquefied Petroleum Gases ANSI/NFPA 58.
16. Be sure that all guards are replaced before use.
17. Do not use this heater on LP gas cylinders larger than 20 lbs. capacity
18. Gas supply connections should be checked by using a 50/50 soap and water solution. Never use a flame
to check for gas leaks.
19. Keep heater area free from combustible materials such as gasoline, paint thinners and other flammable
vapors and liquids. Dust is combustible. Do not use heater in areas of high dust concentration.
20. The hose assembly shall be visually inspected prior to each use of the heater. If it is evident there is excessive
abrasion or wear, or the hose is cut, it shall be replaced prior to the heater being put into operation. The
replacement hose assembly shall be that specified by the manufacturer.
21. Do not restrict air inlet or outlet areas of the heater.
22. Always attach the heater in an upright (vertical) position. Never attach the heater in a horizontal position.
This will lead to dangerous and improper operation.
23. Operate heater in a manner that will not directly expose it to water, rain or dripping water.
24. Always disconnect and remove the heater from the LP cylinder after use.
PROPANE (LP) SUPPLY
1. You must provide the propane gas cylinder(s). Use this heater only with a propane vapor withdrawal supply
system. Refer to Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas , ANSI/
NFPA 58. Your local library or fire department will have this booklet.
2. LP Characteristics; Flammable, explosive under pressure, heavier than air, and pools in low areas.
3. In its natural state, propane has no odor, but for your safety an odorant that smells like rotten cabbage has
been added.
4. Contact of propane (LP) gas with the skin can cause freeze burns.
5. Heater is manufactured for use with LP gas only. DO NOT attempt to convert to any other gas. Such
modifications are dangerous, and will void warranty.
6. When heater is not in use, LP cylinder must be turned OFF.
7. Be sure that the LP cylinder is located on a level and stable surface. The burner should be at least 24 inches
from the floor.
8. Do not use this heater in a basement or below ground level. Propane (LP) is heavier than air, and will always
seek the lowest level. If you suspect a leak, shut off the valve at the LP cylinder immediately.
9. Do not use a flame to check for leaks! Use a 50/50 solution of dish soap and water to check for leaks.
Repair any leaks before attempting to re-light the heater.
10. Check the "O" ring on the heater inlet fuel connector for damage before each use. Replace if damaged or
worn.
11. Always store the LP cylinder outdoors, but not in an enclosed area. Never store the LP cylinder near high
heat, direct sunlight or open flames. Never store the LP cylinder indoors.
12. The amount of LP gas used by this heater varies. The two factors that will determine this are as follows:
a. The amount of gas in the cylinder.
b. The temperature of the cylinder and surrounding area.
WARNING: EXTREMELY HOT DURING OPERATION. DO NOT TOUCH ANY METAL COMPONENTS
WHILE IN OPERATION. KEEP GASOLINE AND ANY OTHER FLAMMABLE LIQUIDS AWAY
FROM HEATER.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
DO NOT DIRECT HEATER DISCHARGE TOWARDS ANY PROPANE CYLINDER LOCATED WITHIN
20 FEET OF THE HEATER.
Propane Tank Top Heaters Manual
GENERAL SAFETY INFORMATION
11

Publicité

loading

Ce manuel est également adapté pour:

Mh-0030-im11