Do not heat up the glass jug when it is empty�
Rinse out the glass jug with hot water after use�
Clean the glass jug in the dishwasher (up to
60 °C) or with standard detergent and a soft
brush� Do not use any abrasive agents or sharp
objects�
Do not place the hot glass jug on cold or wet
surfaces�
Do not hold the glass jug over people�
Switch off the hot plates as soon as the glass jugs
are empty�
Take note of any visible damage or malfunctions�
Obvious malfunctions include water leaks, odors
and heat formation, unusual noises, as well as
error messages on the display� In the event of
any unusual situation:
Disconnect the mains plug
͵
Switch off the water supply
͵
Contact customer service
͵
Have the machine checked and repaired by
͵
customer service
Clean the machine regularly� Impurities could
cause health problems�
Descale the machine regularly� Only use Melitta
Cafina
quick descaler, art. no. 40203.
®
Warning notes
cautiOn
Minor injuries!
Identifies hazards that could result in minor injuries�
attentiOn
Property damage!
Identifies the risk of possible property damage�
31807 • 20221101
technical data
Machine specifications
Dimensions (W x D x H)
͵ with glass jug
͵ with insulated jug
Installation weight
͵ with glass jug
͵ with insulated jug
Integrated water tank
capacity
Operating data
Hourly output
Max� immediate
dispensing quantity
Permissible ambient
temperature
Permissible air humidity
Noise level
®
electrical connection
Power supply
Power consumption
͵ with glass jug
͵ with insulated jug
Fuse protection provided
by customer
Mains connection
Water connection
Fresh water connection
Fresh water pressure
Fresh water carbonate
hardness
Technical data
230 x 420 x 470 mm
230 x 420 x 635 mm
approx. 15 kg
approx. 18 kg
2.0 l
125 cups/hour (125 ml)
15 cups/6�5 minutes
+ 5‑35 °C
< 80 % non‑condensing
< 70 dB(A)
200‑240 V, 50‑60 Hz
1470‑2110 W
1360‑1960 W
16 A (required)
1.8 m mains cable with
shock-proof mains plug
G ¾" outer thread
At least 0.25 MPa
(2.5 bar) at approx. 2 l/
min, a pressure reducer
is required for static
pressures higher than
0.6 MPa (6 bar)
For very hard water, we
recommend using a water
filter (e�g�, BRITA Purity)
13