Securing the Toilet Base & Installation of Motor Support
Note: To help with the installation, the discharge pump assembly may be removed prior to completing this task.
Bolt down the toilet base using the selected hardware (page 4). Tighten all fixings securely, if you are not using self locking
nut, use nut locking compound.
IMPORTANT: Install Motor Support.
• It is recommended the motor support block is fitted to the mounting surface rather than the motor casing.
• Ensure the mounting surface is clean and dry,
• Remove the 3m protective tape, position the support block so that it is directly under the rear section of the
motor when connected to the toilet base.
• Ensure it is located in the center of the motor, approximately 1" (2.5cm) from the rear of the motor casing.
• The support block must not overlap the rear of the motor casing as this will interfere with the motor cover.
• Press the support block down firmly to ensure the block adheres to the mounting surface.
• Connect the discharge pump to the base ensuring the quick release C-clip is securely snapped into place.
• Connect the discharge hose (if disconnected during base mounting section).
• Fit the seat and lid using the adjustable fastenings supplied with it.
Testing
• Before testing, ensure all connections are secure.
• Ensure that the battery is fully charged, and that the circuits are live.
• Turn on fresh water pump for the fresh water toilet or open the seacock for the raw water toilet.
• Refer to the section — Operating Instructions.
• To prime the solenoid valve or rinse pump on first installation, operate the 'eco mode' function several times until water
flows into the toilet bowl. Thereafter, they are automatically switched by the control panel.
• Inspect all hose connections and discharge pump assembly, ensure none are leaking. If any leaks are found, check all
hose clips are secure, check discharge pump C-clip is fully snapped into toilet base housing.
• ON COMPLETION — CLOSE BOTH SEACOCKS or turn off fresh water pump.
SAFETY: Ensure that this INSTRUCTION MANUAL reaches the owner, skipper or operator of the
craft as it contains essential safety information.
Operating Touch Pad Controller
The Quiet Flush toilet range features a multifunction 'one touch' control pad offering three options:
The Quiet Flush E2 Toilet features a 'one touch' control pad offering three options – 'eco flush' and 'normal flush' and
'dry bowl'
• Press 'eco' or 'normal' to activate flushing cycle. For first use the system will need to be primed. Activate 'eco' or 'normal'
function 2-3 times to ensure system is fully primed with water held in the bottom of the bowl.
• 'eco' and 'normal' — Ensure rinse water is present in bowl before use. Use toilet, then activate desired flush function.
An additional volume of water will be added followed by the discharge function. Water will then be added to the bowl
ready for next use.
• 'dry bowl' is a hidden function — Activate this function to ensure bowl is discharged with no new rinse water added. This
will leave the bowl dry — desirable when sailing/motoring to avoid splash. To activate, press and hold both 'eco flush'
and 'normal flush' simultaneously for 4 seconds, the discharge pump will activate without any additional rinse water
entering the bowl. Ensure 'eco' or 'normal' flush function is activated to add water to bowl before using the toilet.