3
Refer to the information in chapter „Electrical connection" before connecting the
X
X
appliance.
Connect the appliance to the power supply.
X
X
4
Fit the appliance in the worktop correctly.
X
X
Apply the sealing strip around the hole and position the hob.
X
X
Fix the appliance with the screws and brackets.
X
X
Remove any excess sealing strip.
X
X
5
If the appliance is not installed above an oven:
Arrange a separator baffle.
X
X
6
Minimum flame adjustment
Remove the knobs (push-on type).
X
X
Light the burners.
X
X
Adjust the minimum flame by turning the adjustment screw clockwise to decrease
X
X
the flame and anticlockwise to increase it. The screwdriver for adjustment is
supplied with the accessories.
Connection to gas supply
Connect the appliance to the gas supply in compliance with the current regulations,
only after making sure it is arranged for the type of gas to be used. Otherwise, carry
out the operations described in the section on „replacing injectors".
For liquid gas use pressure regulators complying with the current regulations.
Connection to the gas supply can be made in two ways:
A
Connect the gas hob using a 12 mm diameter rigid copper pipe (3). To ensure a
X
X
good seal, use the elastomer gasket supplied as an accessory (1).
B
Connect the hob using a continuous-surface flexible steel tube (2).
X
X
Also in this case, to ensure a good seal use the gasket supplied as an accessory (1).
Make sure to comply with the current regulations on gas systems.
After carrying out the connection use soapy water to check for any leaks.