Accessing the hob
To access the tray containing the functional parts, proceed as follows:
Remove the grids, burner caps and flame-spreaders;
X
X
Remove the knobs, sliding them off their pins;
X
X
Remove the screws that fix the burners to the hob;
X
X
Lift the hob.
X
X
Important
When converting the appliance to a different type of gas, place the corresponding
sticker (supplied as an accessory) in the special space on the dataplate. For
operation with LPG (G30 or G31), the minimum flame adjustment screw must be
fully screwed down. These appliances are supplied in cat. II 2H3+.
REPAIR
If the power cable is damaged, it must be replaced by the manufacturer or the
service or else by a person with similar qualifications, in order to avoid any risks.
Warning!
Before attempting any repairs on the appliance, disconnect the power supply.