troubleshooting
Problem
Pump has following problems: failure
to produce pressure, erratic pressure,
chattering, loss of pressure, low water
volume.
detergent fails to mix with spray.
engine runs good at no-load but "bogs" when
load is added.
engine will not start; shuts down during
operation or starts and runs rough.
engine lacks power.
Product specifications
Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137.9 BARS (2,000 PSI)*
Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.2 liters/min (1.9 GPM)
Water Supply Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38ºC (100ºF) MAX
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 cc
Spark Plug Gap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.76 mm (0.030 in.)
Fuel Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.95 Liters (1.0 Qt.)
Oil Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6 Liters (20 Ounces)
Power ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of Automotive Engineers) code J1940 (Small Engine Power &
Torque Rating Procedure), and rating performance has been obtained and corrected in accordance with SAE J1995 (Revision 2002-05). Torque values are derived at 3060 RPM;
horsepower values are derived at 3600 RPM. The gross power curves can be viewed at www.BRIGGSandSTRATTON.COM. Net power values are taken with exhaust and air cleaner
installed whereas gross power values are collected without these attachments. Actual gross engine power will be higher than net engine power and is affected by, among other
things, ambient operating conditions and engine-to-engine variability. Given the wide array of products on which engines are placed, the gas engine may not develop the rated gross
power when used in a given piece of power equipment. This difference is due to a variety of factors including, but not limited to, the variety of engine components (air cleaner,
exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature, humidity, altitude), and engine-to-engine variability. Due
to manufacturing and capacity limitations, Briggs & Stratton may substitute an engine of higher rated power for this Series engine.
* This pressure washer is rated in accordance to the Pressure Washer Manufacturers Association (PWMA) standard PW101-2010 (Testing and Rating Performance of Pressure
Washers).
14
cause
1. Nozzle in low pressure mode.
2. Water inlet is blocked.
3. Inadequate water supply.
4. Inlet hose is kinked or leaking.
5. Clogged inlet hose screen.
6. Water supply is over 100°F (38°C).
7. High pressure hose is blocked or leaks.
8. Gun leaks.
9. Orifice is obstructed.
10. Pump is faulty.
1. Detergent siphoning tube is not submerged.
2. Detergent siphoning tube is clogged or cracked.
3. Nozzle is in high pressure mode.
4. Check ball stuck in detergent siphoning system.
Engine speed is too slow.
1. Low oil level.
2. Dirty air cleaner.
3. Out of fuel.
4. Stale fuel.
5. Spark plug wire not connected to spark plug.
6. Bad spark plug.
7. Water in fuel.
8. Excessively rich fuel mixture.
Dirty air filter.
correction
1. Pull nozzle backward for high pressure mode.
2. Clear inlet.
3. Provide adequate water flow.
4. Straighten inlet hose, patch leak.
5. Check and clean inlet hose screen.
6. Provide cooler water supply.
7. Clear blocks in outlet hose.
8. Replace gun.
9. Clean orifice.
10. Contact local service facility.
1. Insert detergent siphoning tube into detergent.
2. Clean or replace detergent siphoning tube.
3. Push nozzle forward for low pressure mode.
4. Unstick check ball as described in Detergent Siphoning
Check Ball.
Move throttle control to Fast position. If engine still "bogs
down", contact local service facility.
1. Fill crankcase to proper level.
2. Clean or replace air cleaner.
3. Fill fuel tank.
4. Drain fuel tank; fill with fresh fuel.
5. Connect wire to spark plug.
6. Replace spark plug.
7. Drain fuel tank; fill with fresh fuel.
8. Contact local service facility.
Replace air filter.
common service Parts
PumpSaver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6039
O-Ring Maintenance Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191922GS
Water Inlet Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B2384GS
Air Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .698369 or 5088
Resistor Spark Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .802592 or 5095
Long Life Platinum Spark Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5062
Engine Oil Bottle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100005 or 1000028
Fuel Stabilizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000120 or 100117
Spark Arrester. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398067
Briggsandstratton.coM