6.
Then slowly and carefully lower the load by turning the release valve
counterclockwise (use the slotted end of the handle) in extremely small
increments.
PRESSURE DROP
Apply the air consumption and pressure rate numbers to the tool' s air inlet, not
the compressor' s outlet. Calculate the pressure drop for your air supply set-up
and increase the compressor outlet pressure to compensate. Make sure you do
not exceed the maximum pressure for any part of your air supply system.
Installing a pressure gauge at the tool inlet is the best way to measure the air
pressure and adjust the compressor' s output.
CARE & MAINTENANCE
1.
Maintain the tool with care. A tool in good condition is efficient, easier to
control and will have fewer problems.
2.
Inspect the tool components periodically. Repair or replace damaged or
worn components. Only use identical replacement parts when servicing.
3.
Keep the tool handles or gripping surfaces clean and dry.
4.
Maintain the tool' s labels and name plates. These carry important
information. If unreadable or missing, contact Princess Auto Ltd. for
replacements.
5.
Have a qualified technician inspect the jack:
a.
Once a year.
b.
After receiving a shock load. Take the jack out of service until the
technician certifies that it is safe to use.
WARNING! Only qualified service personnel should repair the tool. An
improperly repaired tool may present a hazard to the user and/or others.
HYDRAULIC MAINTENANCE
HYDRAULIC RAM MAINTENANCE
Monthly maintenance is recommended for the hydraulic ram. Any restrictions
due to dirt, rust, etc. can cause the either slow movement or extremely rapid
jerks, damaging the internal components. The following steps are designed to
keep the pump maintained and operational.
www.princessauto.com / 1-800-665-8685