PE 2002T
PE 2006T
7.0 TROUBLESHOOTING
PROBLEMS
The lift does not work. No
reaction.
Raising push-button pressed,
motor rotating, but lift does
not move.
No reaction on pressing the UP
push-button.
Carriage P1 is in a higher or
lower position with respect
to carriage P2.
On pressing the DOWN push-
button the carriages stop at
different heights.
On pressing the DOWN push-
button, the carriages do not
go down.
7.1 SPARE PARTS
Spare parts purchase orders shall be submitted to the manufacturer, and shall include the following
information:
•
Type, version, and serial number of the lift. These data are stamped on the plate fixed to all
equipment (§ 1.5).
Spare parts table number, and part number.
•
Part description and required quantity.
•
•
Shipping means. If this item is not specified, the manufacturer, even devoting special care
to this service, is not liable for any shipping delay due to force majeure.
Shipping charges always have to be borne by the consignee. Goods travel at consignee's risk, even
if sold free at destination.
In case of request, please refer only to the position number of each single item of the spare parts
table.
PE 2007T
POSSIBLE CAUSES
- Switch/Disconnector in OFF postion.
- No power supply.
- Cable connections.
- Burnt-out fuses.
- Motor direction of rotation.
- Not enough oil inside tank.
- Discharge solenoid valve (EV1) faulty.
- Cable connections.
- Micro-switch FC1 tripped or faulty.
- Presence of air in the system.
- Misalignment.
- Safety valve operation.
- P2 carriage is stuck.
- FC2 tripped or faulty
ACTIONS
- Turn the Emergency Switch/Disconnector
to the ON position.
- Check cause.
- Check connections.
- Replace.
- Reverse cable connections.
- Restore oil level.
- Check the solenoid valve and replace, if
required.
- Check connections.
- Check.
- Bleed air and re-align (§ 3.4.5)
- Align the carriages. (§ 4.4.6.1)
- Check.
- Raise the carriage and release it.
- Check.
77