PE 2002T
PE 2006T
6.1.3 RUBBER-COATED PADS
Check their conditions. If worn-out or broken, change them.
6.1.4 EMERGENCY DISCONNECTOR/OFF PUSH-BUTTON
1)
Turn Emergency Switch/Disconnector (19, Fig. 1) to «ON».
2)
Carry out any operation required for LOWERING or RAISING.
3)
Turn Emergency Switch/Disconnector (19, Fig. 1) to «OFF»: the lift must stop immediately.
6.2 PERIODICAL MAINTENANCE
6.2.1 EVERY WEEK
•
Check safety devices every week, as specified in this manual.
•
Check hydraulic oil level as follows:
•
Bring the carriages fully down and check that level is at the mark, 2 ÷ 3 cm under the hole
(8, Fig. 14).
•
If necessary, top up with hydraulic oil as indicated in the technical specifications through
the plug (9, Fig. 16).
6.2.2 EVERY MONTH
•
Check lift screws correct tightening;
•
Check hydraulic system correct sealing; tighten loose unions, if necessary;
•
Check the condition of hydraulic hoses; if worn out, change them with new equivalent ones.
6.2.3 EVERY 200 OPERATING HOURS OR EVERY 5 YEARS, AT THE LATEST
•
Replace hydraulic system oil, discharging the exhausted oil from tank. Clean oil filter. For
this operation, please refer to the relevant table showing the supplied spare parts.
If these operations are carried out with the utmost care, the user will find the equipment in perfect
working conditions upon lift restart.
6.3 EMERGENCY HYDRAULIC PUMP
An emergency hydraulic pump can be installed upon request. This pump will be used in case of
power cut-off and, on some occasions - as described in par. «5.5 Emergency Lowering» - in case
of any lock at the lowering system.
Please note that the Manufacturer is always at your disposal for any service and spare part needs.
76