8 Maintenance

Warning:
-
When carrying out work on the device, please disconnect the power supply.
-
The External Control Kit does not contain any parts that need regular maintenance.
-
Just the outside parts of the External Control Kit on the outside of the machine panel can be
cleaned with a moist cloth.
-
Check the manual for the CMM Easy for maintenance to the CMM Easy.

9 Faults

Warning:
-
When carrying out work on the device, please disconnect the power supply.
-
Repairs must be carried out by a skilled electrical fitter.
Schedule 4, faults
Problem
LED's on
CMM Easy do not
light up
LED on External
Control Kit do not
light up
LED's on
CMM Easy do not
light up orange but
keep blinking
(green)
LED's CMM Easy
light up red
LED's CMM Easy
blink red
LED's CMM Easy
blink red-green
ExternalControlKit_CMMEasy_UM_9752098550_NL_D_GB_F_V2_0
Possible cause
No mains voltage
Wiring problem
No signal at the "Remote"-input
High voltage set too low
Label(s) between electrodes and
earth are too small or not fitted,
flash-over between electrode
and die
Output voltage set too high,
flash-over at electrode
Short-circuit between electrode
or high voltage cable and earth
Mains voltage too low
"Cycle OK"-output overloaded
Generator overheated or
overloaded
Solution
Switch on mains voltage 24V DC
Trace connection problem and
repair, see 5.3
Supply 24 V DC (±3 V)
"Remote"-input
Increase output voltage by
increasing setpoint (6.1/6.2/6.3)
Check presence label(s) or use
correct size, insulate electrode or
increase distance to die (part)
Lower output voltage by lowering
setpoint or increasing distance to
earth
Track and resolve short-circuit
Restore mains voltage 21-27 V DC
to M12-connector
Remove overload
(24 V DC >50 mA)
Surrounding temperature <55ºC,
resolve overload; see
aforementioned solutions
at the