9 - Operating problems
START-UP
Compressor does not start,
eventhough the desired temperature is lower than the
temperature in the room.
Compressor does not stop.
DURING OPERATION
A liquid crystal display indicates a temperature below the
temperature you set.
A liquid crystal display indicates a temperature above the
temperature you set.
Note: The refrigeration unit must only be serviced by a refrigeration technician, who must check the circuit for leaks before putting back into service. Any servicing
of the electrical circuit must only be performed by an electrician.
NB: Whatever the case, if your cabinet does not seem to be operating normally, unplug it and call your dealer.
1-Check the wall socket by plugging in any type of electrical device, and make sure that the on/off switch is
in the "I" position.
2-Press the TEST button and check that the two red and green indicator lights light up.
3-Turn the low temperature setting knob (or the single temperature setting knob for Viellitheque type cabinets)
as far as it will go counter-clockwise, and make sure that the green indicator light lights.
4-If the compressor still does not start after steps 2 and 3, contact your dealer.
1- Place your hand on the condenser (metal screen at the back of your cabinet) to check its temperature.
Contact your dealer if cold.
2-If the condenser is hot, set the cold temperature as high as possible (as far as it will go clockwise) and make
sure that the cold circuit operation indicator goes off. If the compressor does not stop, unplug the cabinet and
contact your dealer.
1-Check the temperature set-points (see pages 7 to 9 of this manual).
2-Check that the red hot circuit operation indicator light is on.
3-Press the TEST button, and check that the two red and green indicator lights on the right side of the panel
are on. If either step 2 or 3 is incorrect contact your dealer.
1-Check the temperature set-points (see pages 7 to 9 of this manual).
2-Check that the green cold circuit operation indicator light is on.
3-Press the TEST button, and check that the two red and green indicator lights on the right side of the panel
are on. If either step 2 or 3 is incorrect contact your dealer.
Contact your dealer, if after adjusting set-points and testing hot and cold circuit indicator lights either of the
two problems above are not corrected.
- 17 -