Your EuroCave wine cabinet is a tried and tested, easy-to-use appliance. The following few maintenance
operations will enable your cabinet to provide you with many years of faithful ser vice.
- Each year, you should replace the active carbon filter located in the upper breather hole of your cabinet.
Manually remove the carbon filter (see diagram opposite). You can obtain a replacement carbon filter from
your usual retailer. The replacement part should have an original manufacturer's guarantee.
- Clean and dust the condenser (metal grid located the length of the rear wall of the cabinet) twice a year.
- W hen cleaning the back of the cabinet, and before moving it, make sure it has been disconnected from the
mains power supply and that there are no bottles left in the cabinet.
- O nce a year completely clean the interior of your cabinet after emptying it and ensuring it disconnected
from the power supply (use water and a non abrasive cleaning product, then rinse carefully).
Checking the appliance regularly and, if you suspect that something is not functioning
correctly, notifying your retailer of this possible anomaly, is the best way to ensure that your
wine cabinet will provide you with long and faithful service.
- If compressor does not start, even though the desired temperature is lower (more than 4°F).Then check the wall socket by plugging in any type of electrical
device, and make sure that the on/off switch is in the
- If the compressor does not stop, place your hand on the condenser (metal screen of your cabinet) to check its temperature. Contact your dealer if cold.
If the condenser is hot, set the cold temperature as high as possible. If the compressor does not stop, unplug the cabinet and contact your dealer..
In all cases, if your cabinet does not appear to be operating correctly contact your EuroCave wine cabinet retailer.
Any inter vention on the refrigeration unit must be carried out by a qualified
refrigeration technician who will check the circuit is waterproof before powering up. In
the same way, any inter vention on the electrical circuit should be carried out by a qualified
electrician.
- In the event that the temperature measurement sensor is faulty, the symbol display EO appears.
Use of a glass door can change your wine cabinet's performance in certain extreme
temperature conditions.
8 - E
VERYDAY MAIN TEN AN CE
9 - O
PERATIN G AN O MALIES
position.
13