Scope of delivery
Key to Fig. 1:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Cold catalyst filter (black) and bio filter (green)
[4]
Drainage elbow with gasket (for outdoor unit with floor or wall
mounting bracket)
[5]
Remote control
[6]
Remote control holder with fixing screw
[7]
Fixing materials (5 screws and 5 wall plugs)
[8]
Set of printed documents for product documentation
[9]
5-core communication cable (optional accessory)
[10] 4 anti-vibration couplings for the outdoor unit
2.6
Product dimensions and minimum clearances
2.6.1
Indoor unit and outdoor unit
Figures 2 to 4.
2.6.2
Refrigerant lines
Key to Fig. 5:
[1]
Gas-side pipe
[2]
Liquid-side pipe
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 5, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Maximum pipe
length
CL5000i 26 E
CL5000i 35 E
1) Gas side or liquid side
2) Measured from lower edge to lower edge.
Table 63 Pipe Length and Drop Height
Unit type
Liquid side [mm]
CL5000i 26 E
6.35 (1/4")
CL5000i 35 E
6.35 (1/4")
Table 64 Pipe diameter depending on unit type
Pipe diameter [mm]
6.35 (1/4")
9.53 (3/8")
Table 65 Alternative pipe diameter
Specification of the pipes
Min. piping length
Standard piping length
Additional refrigerant when the piping
length exceeds 5 m
Piping Thickness
Thickness of insulation against heat
Material of insulation against heat
Table 66
Climate 5000i – 6721824787 (2024/01)
Maximum difference
1)
2)
[m]
in height
[m]
≤ 25
≤ 10
≤ 25
≤ 10
Pipe size
Gas side [mm]
9.53 (3/8")
9.53 (3/8")
Alternative pipe diameter [mm]
6
10
3 m
5 m
12g/m
≥ 0.8 mm
≥ 6 mm
Polyethylene foam
2.7
Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant. The
device is hermetically sealed. You will find the information on the
refrigerant according to the Regulation (EU) No 517/2014 on
fluorinated greenhouse gases in the operating instructions of the device.
Information for the installer: If you refill refrigerant, enter the additional
charge size and the total charge size of the refrigerant in the table
"information on refrigerant" of the operating instructions.
3
Installation
3.1
Before installation
CAUTION
Risk of injury from sharp edges!
▶ Wear protective gloves during installation.
CAUTION
Danger of burns!
During operation the pipes become hot.
▶ Make sure, that the pipes cooled down before touching them.
▶ Check the scope of delivery for damage.
▶ Check whether a hissing sound due to negative pressure can be
detected when opening the pipes of the indoor unit.
3.2
Requirements for installation site
▶ Observe minimum clearances ( Figs. 2 to 3).
Indoor unit
▶ Do not install the indoor unit in a room in which open ignition sources
(for example: open flames, an operating wall mounted gas boiler or
an operating electric heating system) are in operation.
▶ The installation site must not be higher than 2000 m above sea level.
▶ Keep the air inlet and air outlet clear of any obstacles to allow the air
to circulate freely. Otherwise bad performance and higher noise level
may occur.
▶ Keep TV, radio and and similar appliances at least 1 m away from the
unit and the remote control.
▶ Mount the indoor unit on a wall that absorbs vibrations.
▶ Take minimum room area into account.
Unit type
Installation height
CL5000iU W 26 E
CL5000iU W 35 E
Table 67 Minimum room area
If the installation height is lower, the floor area must be accordingly
larger.
Outdoor unit
▶ The outdoor unit must not be exposed to machine oil vapour, hot
spring vapour, sulphur gas, etc.
▶ Do not install the outdoor unit directly next to water or where it is
exposed to sea air.
▶ The outdoor unit must always be kept free of snow.
▶ There must be no disruption caused by exhaust air or operating
noise.
Installation
Minimum room area
2
[m]
[m
]
≥ 1.8
≥ 4