Design Guide - Single Integrated Installation
SINGLE INTEGRATED INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
84" (213.4)
PRODUCT
ENCLOSURE
WIDTH
17 13/16
18
45.2
23 13/16
24
60.5
29 13/16
30
75.7
35 13/16
36
91.0
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
For a 90° door swing, allow 5 1/8 (13.0 cm) minimum
clearance to a wall.
When installed in a corner, allow 15" (38.1 cm) for a full 115°
door swing on 18" and 24" models. Allow 16 9/16" (42.1 cm)
on 30" models. Allow 19" (48.3cm) on 36" models.
31-1000600 Rev. 1
Enclosure Width
(See Chart)
C
D
A
B
ELECTRIC
WATER
A
B
C
D
4 1/8
3 1/2
7 1/2
2
10.5
8.9
19.1
5.1
4 3/8
5
9 1/2
4
11.1
12.7
24.1
10.2
4 3/8
5
9 1/2
4
11.1
12.7
24.1
10.2
8
9
18
9
20.3
22.9
45.7
22.9
6" (15.2)
Finished
Return
6"
2 1/2" (6.4)
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 25".
Additional Specifications
A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall. Electrical must be located on rear wall
as shown.
The water line should be 1/4" O.D. copper tubing or
QuickConnect™ kit (WX08X10006) between the cold
water line and water connection location, long enough
to extend to the front of the unit (8' [2.4 m]). Installation
of an easily accessible shut-off valve in the water line
is required.
cabinet exterior is recommended on interior on all sides
and top at front of opening.
require Heater Unification Kit.