MODELS
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
(Silicone)
MODELS
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
(Silicone)
MODELLI
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
(Silicone)
MODELLI
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
(Silicone)
The data plate is on the front panel (see diagram in electric connection item) and has all the data necessary for the
connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
GB
TECHNICAL DATA TABLE
FT...-74ET... FT...-76ET... FT...-78ET... FT...-712ET... FTC-74ET
40x70x90
60x70x90
400V 3N 50Hz
400V 3N
50Hz
6.5 A
13 A
4.5 KW
6 kW
5x1 mm²
5x1,5 mm²
FT...T-74ET... FT...T-76ET... FT...T-78ET...
40x70x29h
60x70x29h
400V 3N 50Hz 400V 3N 50Hz 400V 3N 50Hz 400V 3N 50Hz 400V 3N 50Hz
6,5 A
13 A
4,5 kW
6 kW
5x1 mm²
5x1,5 mm²
TRANSFORMATION
FT...-74ET...
FT...-78ET...
FT...T-74ET...
FT...T-78ET...
230Vac 3 50/60Hz 230Vac 3 50/60Hz
11,3 A
4,5 kW
4x1,5 mm²
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
20
IE
80x70x90
120x70x90h
400V 3N
400V 3N
50Hz
50Hz
13.1 A
16.5 A
9 KW
12 KW
5x1.5 mm²
5x2,5 mm²
FTCT-74ET
80x70x29h
40x70x29h
13,1 A
9 kW
5x1,5 mm²
FTC-74ET
FTCT-74ET
230Vac 3 50/60Hz
22,59 A
6,78 A
9 kW
2,7 kW
4x2,5 mm²
4x1 mm²
FTC-74ET
FTCT-74ET
230Vac 50/60Hz
11,74 A
2,7 kW
3x1,5 mm²
FTC-78ET
40x70x90
80x70x90
400V 3N
400V 3N
50Hz
50Hz
3,9 A
7,8 A
2,7 kW
5,4 kW
5x1 mm²
5x1 mm²
FTCT-78ET
80x70x29h
3,9 A
7,8 A
2,7 kW
5,4 kW
5x1 mm²
5x1 mm²
FTC-78ET
FTCT-78ET
230Vac 3 50/60Hz
13,56 A
5,4 kW
4x2,5 mm²
FTC-78ET
FTCT-78ET
230Vac50/60Hz
23,48 A
5,4 kW
3x2,5 mm²