Télécharger Imprimer la page

Toto NEOREST 500H MS952CUMG Manuel D'installation page 2

Publicité

EN
Install the product properly according to this installation manual for best performance. When the installation work is
complete, give a detailed explanation of how to use this product to the customer.
Safety Cautions
Read these "Safety Cautions" carefully before starting installation work. Install the product properly.
This manual uses various indications to ensure a proper, safe installation and to prevent injury to the customer,
injury to other people and damage to property.
The symbols should be interpreted as follows.
Caution
Improper use or installation of this product may result in injury or property damage.
This symbol is used to indicate no
tampering with this product.
Do not subject the toilet bowl to strong forces or impacts.
Otherwise, the toilet bowl may break causing injury or leaks that may damage property.
Do not excessively bend or twist the water supply hose.
Otherwise, the flexible water supply hose may break causing leaks that may damage property.
Prohibited
Do not remove the water supply filter with the water supply valve being open.
If the water supply valve is not closed, water may gush out causing leaks that may damage property.
Be sure to use the included or specified parts for installation work.
Otherwise, the product may not be installed properly.
Carry out the installation work according to this installation manual.
Required
Otherwise, damage caused by water leaks may occur.
Precaution before installation
Secure the space required for toilet installation and at the same time, check door opening/closing for possible interference.
The remote control signal reception may be degraded and the NEOREST unit may not respond to the remote control if
there are shelves or cabinets on the rear wall at a height of less than 55-1/8"(1400 mm) from the floor.
(Shelves and storage cabinets should be more than 55-1/8"(1400 mm)
from the floor.)
Turn on electricity and water supply to the product after completing all
installation work.
Use care not to damage the end of the connection hose.
The minimum required water pressure (flowing) is 7PSI at 2.64 Gal/min
(0.05MPa at 10 L/min) while the maximum water pressure (static) is
108PSI(0.75MPa).
Please wash away the dust or sand in the water supply pipe completely
before installing the water supply valve.
Make sure before installation that the water supply source and water
drain pipe are in the specified positions according to the diagram.
Water supply Rc1/2"(1/2)
For water supply from the wall
Water supply Rc1/2"(1/2)
For water supply from the floor
2
(Observe these cautions for safety's sake. )
4-1/2"
(115mm±10mm)
4-1/2"
(115mm±10mm)
12"
(305mm±10mm)
PVC water drain pipe
This symbol is used to indicate a
required step in the use of this product.
Caution
Product Diagram ( Installation completed )
15-5/16"
(389mm)
For water supply from the wall
4-1/2"
(115mm±10mm)
4-1/2"(115mm±10mm)
For water supply from the floor
4-5/16 " (109㎜)
(When fully open)
2-5/8 " (67㎜)*1
19-7/8 "
(505㎜)
17-3/8 "
(441㎜)
12"
(305mm±10mm)
*1 When the cleaning lift is up with the toilet lid open.