ID 400E
You can back to the main menu by pressing button 9 (Welding Mode Selection Button / VRD Function)
again.
When you want to turn off the VRD function, you can reach the VRD function screen by pressing and
holding button 9 for 3 seconds. You must turn the pot 2 to turn the VRD function to Off. To return to
the main menu, you must press button 9 again.
İs used for reducing the electrode's tendecy to stick into the weld pool during welding.
Arc Force Adjustment Pot
10
3.2 MMA Welding
• Push the welding mode selection button for selecting the stick electrode welding mode. Stick electrode
welding led ligths.
• Adjust the current via current adjustment konb.
• Below table can be used as a rough reference for mild steel electrodes. For exact parameters, please refer to
the electrode manufacturer's recommendations.
Rutile
Covered Electrode
Recommended Welding Current
2.0
40-60 A
Diameter (mm)
2.5
60-90 A
3.25
100-140 A
4.0
140-180 A
5.0
200-240 A
6.0
260-300 A
• For better ignition turn the HOT START knob clock-wise. Welding arc can drill the metal when it is very thin
and hot start is high.
• ARC FORCE is useful for electrodes which have tendency the knob clock-wise will decrease the tendency to
stick. If ARC FORCE is adjusted too high, spatter increases.
• Start welding. You can observe welding current and voltage by current display and voltage display .
3.3 Touch-Scratch TIG Welding
• Push the welding mode selection button for selecting Touch-Scratch TIG welding mode. Touch-Scratch
welding led lights.
• Adjust the current via current adjustment knob.
• Start welding. You can observe welding current and voltage by current display and voltage display.
3.4 Remote Control (Optional)
• It is possible to control the machine from long distances with the wired remote control options available from
Magmaweld. In this case, the appropriate control socket must be installed on the machine by an authorized
Magmaweld service.
• When the remote control connector is connected to the machine, ampere adjustment knob on the machine is
disabled automatically and current adjustment is made by the remote control.
www.magmaweld.com
Basic
Cellulosic
-
-
60-90 A
60-100 A
100-130 A
70-130 A
140-180 A
120-170 A
200-250 A
160-200 A
-
-
Operation
17
EN