ID 400E
2.3 Mains Plug Connection
• No plug has been connected to the mains cable since there may different types of outlets available in plants,
For your safety, never use the mains cord of the machine without a plug.
construction sites and workshops. A suitable plug must be connected by a qualified technican. Make sure that
the grounding cable marked with
• After connecting the plug to the cable, do not attach it to the outlet at this stage.
2.4 Connection to Mains
When plugging the power plug into the outlet, make sure that the power switch is set to "0".
• Check the 3-phase with a voltmeter before connecting the machine to
the mains. After detecting that each phase is 400V (± 40V), attach the
plug into the wall outlet.
• Start the machine with the on / off switch.
• Turn the machine off by turning the switch back to the "0" position
after hearing the fan sound and seeing the ammeter and voltmeter
lights are on.
• According to the polarity of the electrode to be used, insert
2.5 Connections for MMA Welding
welding cables into the appropriate outlet and tighten them by
turning clockwise.
• Connect the earth clamp tightly to the workpiece as close as
possible to the welding area.
2.6 TIG Welding Connections
• TIG torch with a valve should be used.
• Connect the TIG torch power cable to the negative outlet and the
earth cable to the positive outlet of the machine.
• Install the Argon gas regulator onto the Argon gas cylinder.
• Connect the gas hose of the torch to the gas regulator.
Figure 4 : Connecting Gas Cylinder
www.magmaweld.com
and a yellow / green color is present.
Figure 2 : Mains Connection
Figure 3 : MMA Welding Connections
Figure 5 : TIG Welding Connections
Installation
15
EN
USER MANUAL