ATTENTION
Product damage due to incorrect storage
- Store the product protected against dirt, dust
and moisture.
- Store the product in its original packaging.
1. Store the product in a dark, dry and frost-free
place that is inaccessible to unauthorised per-
sons.
2. The optimum storage temperature lies between 5
and 30 °C.
3. Store the operating manual with the product.
17. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cables used must also comply with these
regulations.
• The product fulfils the requirements of EN 61000-
3-11 and is subject to special connection require-
ments. This means that use at any freely selectable
connection points is not permitted.
• The device can cause temporary voltage fluctua-
tions in unfavourable mains conditions.
• The product is only intended for use at connection
points that
a) do not exceed a maximum permissible mains im-
pedance "Z" (Zmax = 0.345 Ω), or
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure that the
connection point at which you wish to operate the
product fulfils one of the requirements mentioned,
a) or b). If necessary, consult with your energy sup-
plier in this regard.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
17.1 Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been im-
properly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the
wall outlet
• Cracks due to the insulation ageing
44 | GB
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables of the same designation.
The printing of the type designation on the connec-
tion cable is mandatory.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
If the power cord of this device is damaged, it must be
replaced by the manufacturer, their service depart-
ment or a similarly qualified person to avoid dangers.
17.2 AC motor
• The mains voltage must be 220−240 V~.
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm².
• Extension cables over 25 m long must have a
cross-section of 2.5 mm
.
2
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Data of machine type plate
• Data of motor type plate
18. Disposal and recycling
The device is supplied in packaging to avoid trans-
port damages. This packaging is raw material and
can thus be used again or can be reintegrated into
the raw material cycle.
The device and its accessories are made of differ-
ent materials, such as metals and plastics. Take de-
fective components to special waste disposal sites.
Check with your specialist dealer or municipal admin-
istration!