"BURNERS" TECHNICAL DATA TABLE MOD. PC...-GP, CF...-GP
Burner max 3,5 kW- min. 1,15 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Burner max 5,5 kW- min. 1,55 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Burner max 7,5 kW- min. 2,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Oven burner max 7,3 kW- min 2.2kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
Oven burner max 11 kW -min 3,5kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS
Our appliances are tested and regulated with liquid gas (see data plate).
The conversion or adaptation to another type of gas must be carried out by a specialised technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see "burners" technical data table).
SUBSTITUTING THE NOZZLE IN OPEN COOKING RINGS MOD. PC..., CF...
Remove the grills, the burners and the containers, substitute the nozzles with the right ones, using a suitable spanner,
unscrewing the blockage screw and relative jam nut. After regulating, screw back the screw and the jam nut, regulate
minimum output by turning the screw to the right or to the left until the thermal power reaches 1,2 KW for the burner of
3,5 KW, and 1,8 for the burner of 5,5 KW.
Warning: For functioning with liquid gas, the screw for regulating minimum output must be blocked completely.
CHANGING THE OPEN RING NOZZLES
Main nozzles (Fig. C):
Take the rungs off, remove the burners and trays, with a size 12 spanner substitute the nozzles with the appropriate
ones, regulate the primary air (h) (see the "burner" technical data table) unscrewing the securing screw. Once regulated,
tighten the screw, adjust the minimum flame by turning the screw to the right or left until the thermal power reaches
1,15 kW for the 3,5 kW burner, 1,55 for the 5,5 kW burner and 2,5 kW for the 7 kW burner.
Caution: If liquid gas is being used the minimum adjustment screw must be locked right down.
Pilot nozzles (Fig. D):
Take the rungs off, remove the burners and trays, with a size 8 spanner loosen the nozzle holder unit, with a size 11
spanner unscrew the nozzle holder all the way, with a slotted screwdriver unscrew the pilot nozzle and replace it with
the appropriate one and tighten right down.
GB
IE
IT
CH
12.8 kWh/KG
12.8 kWh/KG
G30
G31
BUTANE
PROPANE
30 mbar
37 mbar
90
50
20
kg/h 0,276
open
115
60
20
kg/h 0,434
open
135
75
20
kg/h 0,591
20
145
75
1x19
0.570 kg/h
12
175
100
1x19
0.859 kg/h
13
38
9.45 kWh/m
G20
NATURAL GAS H
20 mbar
90
145
50
adjustable
20
35
3
kg/h 0,272
m
st./h 0,370
open
open
115
175
60
adjustable
20
35
3
kg/h 0,427
m
st./h 0,582
open
20
135
205
75
adjustable
20
35
3
kg/h 0,582
m
st./h 0,794
20
20
145
205
75
adjustable
1x19
1x27
0.570 kg/h
0.772 m
12
12
175
270
100
adjustable
1x19
1x27
0.859 kg/h
1.164 m
13
13
3
st.
3
st./h
3
st./h