DECLARATION OF COMPLIANCE
The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for the gas
part and with norm 73/23 for the electric part. The installation must be done observing the norms in force particularly
concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
TECNICAL DATA TABLE
DIMENS
MODEL
cm
PC-74G
40x70x90h
80x70x90h
PC-78G
PC-712G
120x70x90h
160x70x90h
PC-716G
CF4-78G
80x70x90h
120x70x90h
CF6-712GV
120x70x90h
CF6-712G
CF4-78GE
80x70x90h
120x70x90h
CF6-712GEV
CF6-712GE
120x70x90h
80x70x90h
PC-74GP
PC-78GP
80x70x90h
PC-712GP
80x70x90h
80x70x90h
PC-716GP
PCT-74GP
80x70x29h
80x70x29h
PCT-78GP
PCT-712GP
80x70x29h
80x70x29h
PCT-716GP
CF4-78GP
80x70x90h
CF6-712GPV
120x70x90h
CF6-712GP
120x70x90h
CF4-78GPE
80x70x90h
120x70x90h
CF6-712GPEV
CF6-712GPE
120x70x90h
INSTALLATION
•
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
•
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power
installed.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
CHECKING FOR CORRECT VENTILATION
Ensure that the air outlets in the place of work are sufficient to guarantee the necessary air exchange, as stated in
paragraph 4.3 of the UNI-CIG. norm 8723.
The appliance may be installed as a single element or in series with other appliances of our production. It is necessary to
observe a minimum distance of 10 cm from the appliance to prevent contact with walls of inflammable material;
adequate measures must also be taken to ensure thermal insulation of inflammable parts, such as the installation of a
protection against radiation; particular attention must be paid in installing the appliances adequately and safely. The feet
are adjustable in height so that differences in level can be avoided.
GB
NOMINAL BURNER CAPACITY kW
Nr.
Nr.
Nr.
Open
Open
Open
ring
ring
ring
3,5 kW
5,5 kW
7,5 kW
1
1
/
2
2
/
3
3
/
4
4
/
2
2
/
3
3
/
3
3
/
2
2
/
3
3
/
3
3
/
/
1
1
1
2
1
1
3
2
2
4
2
/
1
1
1
2
1
1
3
2
2
4
2
1
2
1
1
3
2
1
3
2
1
2
1
1
3
2
1
3
2
IE
IT
CH
TOT. NOM.
CAPACITY kW
El. oven
Gas
400 Vac/3N
Gas
oven
50/60 Hz
kW
kW
/
/
9
/
/
18
/
/
27
/
/
36
7,3
/
25,3
7,3
/
34,3
11
/
38
/
5
18
/
5
27
/
6,9
27
/
/
13
/
/
22
/
/
35
/
/
44
/
/
13
/
/
22
/
/
35
/
/
44
7,3
/
29,3
7,3
/
42,3
11
/
46
/
5
22
/
5
35
/
6,9
35
35
Gas
MAX.
coupling
ABSO
Elect.
ISOR7
RBA
0,02
R1/2GM
0,01
0,02
R1/2GM
0,01
0,02
R3/4GM
0,01
0,02
R3/4GM
0,01
0,02
R3/4GM
0,01
0,02
R3/4GM
0,01
0,02
R3/4GM
0,01
5
R3/4GM
10,4
5
R3/4GM
10,4
6,9
R3/4GM
10,4
/
R1/2GM
/
/
R1/2GM
/
/
R3/4GM
/
/
R3/4GM
/
/
R1/2GM
/
/
R1/2GM
/
/
R3/4GM
/
/
R3/4GM
/
/
R3/4GM
/
/
R3/4GM
/
/
R3/4GM
/
5
R1/2GM
10,4
5
R3/4GM
10,4
6,9
R3/4GM
10,4
POWER
SUPPLY
CABLE
mm²
3x1
3x1
3x1
3x1
3x1
3x1
3x1
5x1,5
5x1,5
5x1,5
/
/
/
/
/
/
/
/
/
/
/
5x1,5
5x1,5
5x1,5