SPLIT 1X1
IX21D5
INSTALLATION INSTRUCTIONS – INDOOR UNIT
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the label on the product box to make sure that the model number
of the indoor unit matches the model number of the outdoor unit.
4.1 SELECT INSTALLATION LOCATION
Before installing the indoor unit, you must choose an appropriate location. The following are standards that
will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
•
Good air circulation
•
Convenient drainage
•
Noise from the unit will not disturb other people
•
Firm and solid—the location will not vibrate
•
Strong enough to support the weight of the unit
•
A location at least one meter from all other electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
•
Near any source of heat, steam, or combustible gas
•
Near flammable items such as curtains or clothing
•
Near any obstacle that might block air circulation
•
Near the doorway
•
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room for a wall hole (see Drill wall hole
for connective piping step) for the signal cable and refrigerant piping that connect the indoor and outdoor
units. The default position for all piping is the right side of the indoor unit (while facing the unit). However,
the unit can accommodate piping to both the left and right.
Fig. 3.1-a
INSTALLATION MANUAL
4. INDOOR UNIT INSTALLATION
57