Parameterisation 9300 series
Load parameter set
Load parameter set
The keypad serves to load a saved parameter set into the main memory when the controller
is inhibited. After the controller is enabled, it operates with the new parameters.
}
Danger!
When a new parameter set is loaded, the controller is reinitialised and acts
ƒ
as if it had been connected to the mains:
– System configurations and terminal assignments can be changed.
Make sure that your wiring and drive configuration comply with the
settings of the parameter set.
Only use terminal X5/28 as source for the controller inhibit! Otherwise the
ƒ
drive may start in an uncontrolled way when switching over to another
parameter set.
)
Note!
After switching on the supply voltage, the controller always loads
ƒ
parameter set 1 into the main memory.
It is also possible to load other parameter sets into the main memory via
ƒ
the digital inputs or bus commands.