INSTALLATION INFORMATION:
Place the ceiling plate in a suitable location using plugs and screws on the ceiling.
Then screw the detector onto the ceiling plate. Press the center of the detector (test
button) for 10 seconds until the red LED flashes 1x and beeps. The SA300 has just
been switched on. Immediately carry out a first test by pressing the center of the detec-
tor (test button) once. see also heading "Testing".
TEST-TASTE
USING, TESTING AND MAINTENANCE:
Using:
The smoke detector is in operation after the SA300 is activated.
Immediately after activating the smoke detector, the red LED gives 1x flash and 1x
beep. The red LED will now light up briefly about every 60 seconds. Once smoke is
detected, the alarm will sound. Once the smoke disappears, the smoke alarm will stop
automatically.
Test:
The entire front of the detector forms the test button, press the front center to test the
SA300.
Press and hold the test button for 1 second. Within 7 seconds, the SA300 gives 2x
a series of 3 beeps and a red LED under the housing lights up 3x. Then the alarm is
still working correctly. Preferably check the detector every week. In alarm status, the
smoke detector generates at least 85dB(A) sound pressure. Do not test the smoke
detector with candles, open fire, cigarettes or similar but use the test button.
Time-out function:
This function will deactivate the alarm for about 10 minutes. This function can be
enabled by pushing the HUSH/TEST button very shortly. The LED will now blink once
every 8 seconds to indicate the deactivated smoke alarm.
After 10 minutes, the alarm will be fully active once again. If there is (still) any smoke in
the environment, the alarm will go off again.
This function can be used repeatedly.
12
�
�
�
�
1
1
ATTENTION:
If the cause of an alarm is unclear, assume it's caused by fire. Immediately
•
evacuate the building.
•
Keep the smoke detectors out of range of children.
•
Protect against dust during rennovations. Without protection the smoke
detectors will lose their functionality.
Maintenance:
The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by
vacuum.
PLAN AN ESCAPE ROUTE:
•
Make a map and mark all locations of doors and windows and a possible escape
route. Note that you may need an escape ladder on high floors.
•
Ensure everyone in the house knows the sound the smoke alarms produce and
regularly practice use of the escape route.
•
Leave the house immediately according to the plan when hearing the alarm. Every
second counts: so respond quickly. If you do not notice smoke or heat, check if
everyone in the house is in a secure location.
•
Do not open any doors without feeling wether the door is warm or if there is smoke
coming from underneath the doors. If it is, do not open that door. If the door is cold,
put your shoulder firmly against the door and open it a small amount to check for
any heat or smoke first.
•
If there is much smoke, keep low and take shallow breaths, preferably through a
moist towel. Call the fire department as soon as you are safe outside.
REPLACING THE BATTERIES:
The detector is supplied using a built-in lithium battery. Under normal conditions the
battery will last at least ten years. If the detector is about to need replacement, the
smoke detector will make a beep sound every 60 seconds for at least 30 days. If the
smoke detector does not function, please contact your supplier.
ENVIRONMENT:
Do not throw away used batteries, but recycle them using your local chemical
depot. Product may not be thrown out as normal waste, but must be recycled
as electrical waste.