Elvox EC25 Mode D'emploi page 16

Carte de commande sans récepteur radio
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
DIAGNOSIS TABLE FOR POSSIBLE INCONVENIENCES ON THE SLIDING GATE SYSTEMS
POSSIBLE INCONVENIENCES
The automation does not work.
The radio control cannot be programmed.
The radio control does not operate.
The automation run cannot be programmed. The protection devices or commands are
WITH 1 MOTOR CONTROL CIRCUIT BOARD
CAUSES
No supply voltage.
Supply voltage fuses blown up.
Commands not operating.
Protection devices activated.
Protection devices activated.
Connections with inverted polarity.
Run out battery.
Circuit board or receiver do not operate pro-
The radio control coding was not
programmed properly.
The radio control codes and those memori-
zed on the circuit board are different.
Run out battery.
The receiver does not operate properly.
Slowing down speed too low
Motor absorption over the limit set in lab.
Replace the fuses with others with the same
Check that all the security devices are acti-
ve (3 green leds lit). Control the photocells
Check that all the security devices are acti-
ve (3 green leds lit). Control the photocells
cables between the radio circuit board and
Check the voltage between terminals 25 (-
perly.
GND) and 26 (+ANT): you should measure:
remove the conductor from terminal 26 and
Effect the acquisition procedure for the radio
Effect the acquisition procedure for the radio
Check the voltage between terminals 25 (-
GND) and 26 (+ANT): you should measure:
nals is lower remove the conductor from ter-
minal 26 and measure the voltages with idle
Check that the 3 green protection leds are
active.
the slowing down speed (Vrall). Check that
the trimmer related to the Vrall is set at half
way. If the gate blocks during the program-
gramming is not possible, effect the run test
press the push-button MEMO on the circuit
board. The automation must open and carry
out the programmed run. The flashing light
By means of a tester, in continuous current
and eliminate possible mechanical attritions.
- 16 -
CHECK UPS / SOLUTIONS
Check the transformer supply voltage
switch.
value.
Check the radio controls and selectors or
push-buttons.
operation or aligning and the connections
related to the protection devices.
operation or aligning and the connections
related to the protection devices.
Control the connection and polarity of
the control circuit board.
Replace the batteries.
V > 10V d.c.
If the voltage between terminals is lower,
measure the voltages with idle system. If
there is no voltage, replace the electronic
circuit board. If the voltage is 12V replace
the receiving circuit board.
code (see instructions).
code (see instructions).
Replace the battery (type 23AE 12V).
V > 10V d.c. If the voltage between termi-
system. If there is no voltage, replace the
electronic circuit board.
If the voltage is 12V replace the receiving
circuit board.
lit and the 4 red control leds are switched
off.
The run programming is to be effected at
ming, increase the slowing down speed
(Vrall) and the clutch too (Friz.) by turning
the trimmer to +. If, in any case, the pro-
set in the lab: remove the supply voltage
from the circuit board, power it again and
and the SPAP must flash. Contact your
customer assistance department.
mode, measure the motor absorption: it
must be lower than 8.5A.
If it overcomes the 4A, check the gate run

Publicité

Table des Matières
loading

Table des Matières