Radiocontrols - Elvox EC25 Mode D'emploi

Carte de commande sans récepteur radio
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
- To enter the programming press the RESET button, on the top right of the card. An audible warning indicates the programming phase has started.
1- Press the RESET push-button for a little
while and then release it.
2- Wait for the acoustic signal (acoustic signal
dwell: 5 sec.)
3- During the acoustic signal press and hold
down the MEMO push-button until the
ORANGE LED switches on.
4- As soon the ORANGE LED switches on,
release the MEMO push-button.
5- The ORANGE LED switches off and the
GREEN LED starts flashing, indicating that
the card is in programming mode.
Start saving the travel:
-
Press the MEMO button on the card again to start the travel. The motor will start and close the gate (if the gate opens instead of closing you will
need to swap over the motor's power cables and repeat the procedure). When the gate closes completely the motor stops and automatically rever-
ses its motion, opening the gate. Wait for complete opening.
-
Press the MEMO button when the gate reaches the desired opening position. Now wait for the pause time, automatic closing time, of the automatic gate system.
-
Press the "MEMO" push-button for the automatic closing after the desired time, the door closes at the V.RAL speed.
If the automatic system cannot close, set the V.RAL trimmer at the maximum. Once the programming is terminated, reset the trimmer to the desired
speed.
The card has now saved the travel for opening, closing and the pause time. If everything has gone well, the green LED (MEMO) will go out.

4.RADIOCONTROLS

The control unit accepts and saves up to 250 different 10 bit radio codes. When the memory is used up an attempt at saving a new code will
generate an audible warning and the green LED (RESET), on entering the new code, will stay on.
Open the cover of the radiocontrol and position the contacts of the 10 dip-switches as preferred (Fig. 10A - Fig. 10B).
4.1. RADIO CODE PROGRAMMING
To enter programming mode, ensure that the 3 safety green leds are switched on and follow the procedure described here:
- Press the RESET button, on the top right of the card. An audible warning indicates the programming phase has started.
- Keep pressed the memo push-buton, the grren LED lights up (memo)
- Press the radiocontrol button for the channel you want to save. If the operation is successful, it is signalled by the green LED (MEMO) blinking and
then staying on. If I enter a different code to the previous ones the green LED (MEMO) blinks again and stays on. After programming, wait for approxi-
mately 10" until the green LED (MEMO) blinks twice and goes out to signal that the radiocontrol programming procedure is over.
Fig. 10A
Fig. 11
Fig. 12
- 11 -
Fig. 10B

Publicité

Table des Matières
loading

Table des Matières