Télécharger Imprimer la page

Parkside PDT 40 B2 Instructions D'utilisation Et Consignes De Sécurité page 34

Publicité

Les langues disponibles

Les langues disponibles

Operation / Maintenance and cleaning
provide any performance increase, but only in-
creases compressed air consumption and ac-
celerates wear on the device.
Switch on the compressor.
Allow the compressor to run once long enough
until maximum tank pressure is reached and the
device is switched off.
Place the compressed air tacker on the workpiece
and press the trigger
NOTE: The compressed air tacker
is equipped with a trigger lock
The fastener will only leave the device
when the mouth of the compressed air tacker is
pressed against the workpiece and the trigger
is actuated.
Check that the fastener has been driven in cor-
responding to the work requirements.
– If the fastener is protruding, increase the air
pressure in 0.5 bar increments.
– If the fastener is too deep, decrease the air
pressure in 0.5 bar increments.
As an alternative, you can accelerate the work
by keeping the trigger
Set the compressed air tacker against the work-
piece.
Press the device against the workpiece until the
mouth
touches it. The fastener will leave the
9
device.
As long as the trigger
time the mouth
9
fastener will leave the device.
Another alternative is to keep the mouth
pressed against the workpiece.
Each time the trigger
will leave the device.
NOTE: Fine adjustment with the knurled screw
is possible.
Turn the knurled screw
to drive the fastener more deeply into the work-
piece.
Turn the knurled screw
drive the fastener less deeply into the workpiece.
Turn the exhaust air aperture
exhaust airflow in the desired direction.
34 GB
.
2
depressed.
2
is kept depressed, each
2
touches the workpiece one
9
is actuated, a fastener
2
downwards in order
7
upwards in order to
7
to guide the
1
After finishing work, disconnect the device from
the compressor.
Removing jammed fasteners
If a staple or nail gets jammed in the magazine
slot, immediately disconnect the compressed
air supply.
Open the magazine
.
chapter "Loading the magazine".
8
Open the face plate
plate quick clamping lever
of the trigger lock
2
Remove the jammed fastener.
Close the face plate
plate quick clamping lever
of the exhaust air aperture
Close the magazine
tacker as described in the chapter "Loading the
magazine".
Maintenance and cleaning
RISK OF INJURY! Be absolutely certain to
disconnect the device from the compressed air
source before cleaning or maintaining it.
Maintenance
Lubrication with oil mister
NOTE: As a treatment stage after the pressure re-
ducer, an oil mister provides continuous and optimum
lubrication of the compressed air tacker. An oil mis-
ter gives off fine drops of oil into the airflow and so
guarantees regular lubrication.
Install the oil mister after the (filter) pressure re-
7
ducer. To do so, insert the nipple of the oil mis-
ter into the quick-release coupling of the (filter)
pressure reducer.
Then connect the compressed air device to the
quick-release coupling provided for it.
as described in the
5
by pulling the face
10
in the direction
11
.
8
by pulling the face
10
in the direction
11
.
1
of the compressed air
5

Publicité