Mounting The Handles On Integrated Units - Bertazzoni REF75PIXL Guide D'installation

Masquer les pouces Voir aussi pour REF75PIXL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
4. PANELS MOUNTING
4.3 Panels dimensions
Example:
84" niche height
36" niche width
4" toe kick height
1/8" gap desired all around
Door panel:
Width: 35-3/4"
Height: 1320 (52")
Drawer panel:
Width: 35-3/4"
Height: 84"-1/8"-54-3/4"-1/8"-4"=25"
If you want a 6" toe kick height
then your bottom drawer panel
height would be 23"
115 (4 ½")
4.4 Mounting the handles on Integrated
units
Handles will have to be mounted on the panels be-
fore they are applied to the fridge. For overlay panel
mounting, remove the screw connecting the stand-
offs to the handle bar.
The overlay screw will pass through the overlay pa-
nel, the stand-off and into the handle bar.
Operate as follows:
>
Drill two holes of 5 mm (1/4 ") on the rear side pa-
nels, insert the supplied screws to the distance indica-
ted in the the table below. To center the vertical handle
(code HV) to the center of the door, split into two the
height of the panel and make a hole at -450 mm (-17
3/4") and one at +450 mm (+17 3/4")
>
Place the handle on top of the holes and insert
the screws through the panel and into the handle
support
[ 2
].
12
(7
)
135
(5
)
[ 1
].
www.universal.bertazzoni.com
3 ( )
1
2
A

Publicité

Table des Matières
loading

Table des Matières