10
12 Model Code
Design (coding of the cell technology and accuracy)
4
= Strain gauge with stainless steel membrane ± 0.25 % FS max.
7
= Strain gauge with stainless steel membrane ± 0.5 % FS max.
Mechanical Connection
1
= G1/2 B DIN EN 837 (only for pressure ranges "1600; 2000 bar")
4
= G 1/4 A ISO 1179-2
E
Electrical connection
4
= Plug connector Binder serie 714 M18, 4 pole
(mating connector not included)
5
= Plug connector EN 175301-803, 3 pole + PE
(including mating connector ZBE 01, IP67)
6
= Plug connector, M12x1, 4 pole (mating connector not included),
Output signal
A
= 4 .. 20 mA, 2 conductor
B
= 0 .. 10 V, 3 conductor
Pressure ranges in bar
HDA 44XX: 001 (-1 .. 1); 2.5; 006; 010; 016; 025; 040; 060; 100; 250; 400; 600; 1000*
HDA 47XX: 006; 016; 040; 060; 100; 250; 400; 600; 1000*
* 1600; 2000; only mech. connection type "1"
Modification number
000 = Standard
On instruments with a different modification number, please read the label or the
technical amendment details supplied with the instrument.
13 Scope of Delivery
HDA 4x00
Operating Instructions
Status: 2023-11-03
HYDAC ELECTRONIC GMBH
HDA 4400 / HDA 4700
HDA 4 X X X – X - XXX – 000
Part no.: 669653