10 Progress
Water softener
level
4
5
6
7
8
9
10
In case of the high water softener setting,
it may occur also in the middle of the
programme, before the rinse (twice during
a programme). Regeneration initiation has
no impact on the cycle duration, unless it
occurs in the middle of a programme or at
the end of a programme with a short
drying phase. In that cases, the
regeneration prolongs the total duration of
a programme by additional 5 minutes.
Subsequently, the rinsing of the water
softener that lasts 5 minutes may begin in
the same cycle or at the beginning of the
next programme. This activity increases
the total water consumption of a
programme by additional 4 litres and the
total energy consumption of a programme
by additional 2 Wh. The rinsing of the
softener ends with a complete drain.
Each performed softener rinse (possible
more than one in the same cycle) may
prolong the programme duration by
another 5 minutes when it occurs at any
point at the beginning or in the middle of a
programme.
Amount of water
(l)
47
25
17
10
5
3
3
All the consumption values
mentioned in this section are
determined in accordance with
the currently applicable
standard in laboratory
conditions with water hardness
2.5mmol/L according to the
2019/2022 regulation (water
softener: level 3).
The pressure and the
temperature of water as well as
the variations of the mains
supply can change the values.
How to set the water softener
level
Make sure the appliance is in user mode.
1. Wait until the indicator
flash, the indicator
flash and the remaining indicators are
off.
The intermittent flashing of the indicator
shows the current setting: e.g. 5
flashes + pause + 5 flashes = level 5.
2. Press the programme button
repeatedly to change the setting. Each
pressing of the programme button
increases the level number. After
reaching the level 10, the count starts
again from the level 1.
3. Press the on/off button to confirm the
setting.
Acoustic signals
Acoustic signals sound when a
malfunction of the appliance occurs. It is
not possible to deactivate these acoustic
signals.
There is also an acoustic signal that
sounds when the programme is
completed. By default this acoustic signal
is deactivated but it is possible to activate
it.
starts to
continues to