30" ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
1. Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surfaces.
b. Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be
solid and level.
Typical cabinet installation
Front
view
30" Minimum*
1"
Minimum to
wall on either
side of range
above 36" height.
36"
FRONT
VIEW
Fig.1
30"
(762 mm)
Minimum
Minimum to wall
1"
on either side of
(25 mm)
range above
36'' (914 mm)
height.
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE
TOP OF THE COOKING SURFACE AND THE BOTTOM
OF AN UNPROTECTED WOOD OR METAL CABINET; OR
24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR
36"
METAL CABINET IS PROTECTED BY NOT LESS THAN
(914 mm)
1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED
WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM
30"
OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS
(762 mm)
THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW
RANGE
ALL DIMENSION REQUIREMENTS PROVIDED ABOVE
OVERALL
TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE
DIMENSIONS
HAZARD, AND INCORRECT COUNTERTOP AND CABINET
CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY
48"
REACHING OVER HEATED SURFACE UNITS, CABINET
(1219 mm)
Maximum
STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS
SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE
PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING
A RANGE HOOD THAT PROJECTS HORIZONTALLY A
49"
MINIMUM OF 5" (127 mm) BEYOND THE BOTTOM OF
(1245 mm)
Maximum
THE CABINETS.
Door Open
30"
Minimum
Minimum to
18"
cabinets on
either side
of range
30"
Minimum
0" clearance below cooking top and at rear of range
30"
(762 mm)
Minimum to
cabinets on
18"
either side of
(457 mm)
range.
0" (0 mm) clearance below cooking top and at rear of range.
25- 3/4"
30"
(654 mm)
(762 mm)
36
(914 mm)
29- 7/8"
(759 mm)
Side
view
13"
Maximum depth
for cabinets
above range top.
25" Max.
SIDE
VIEW
13"
330 mm
Maximum depth
for cabinets
above range top.
25"
635 mm
1/8"
(3 mm)
2-5/8" (67 mm) for models
equipped with warmer drawers
3-1/2" (89 mm) for models
equipped with storage drawers
2
29
/
"
7
8
36
/
"
5
8
"
±
/
1
4
Maximum
26
/
"
6
8
Centerline of
range
47"
Fig.2
All dimensions for electrical outlet location
are maximum.
Dashed cubed area
shows where the electrical outlet must be
installed
for flush to the wall installation.
11"
(279 mm)
22"
(559 mm)
6"
(152 mm)
BACK
VIEW
Wall
Edge
Fig.3