ENTERING A USER WITH AN ASSOCIATED COMMAND
Select U 1. Press ENTER to confirm.
Select a command to associate to the user: The commands are:
- 1 = step-step (open-close);
- 2 = - sequential (open-stop-close-stop);
-3 = only open;
- 4 = partial opening/pedestrian
Press ENTER to confirm...
... a number between 1 and 250 will start flashing for a few seconds. Send the code from the transmitter or
other control device, such as, a keypad selector or a transponder.
Note down the user entered into the LIST OF REGISTERED USERS.
U
i
DELETING A SINGLE USER
Select U 2. Press ENTER. Activate the function and press ENTER to confirm
Use the arrow keys select the number of the user you wish to delete.
Press ENTER to confirm...
... CLr will appear on the screen to confirm deletion.
U
2
GATE-SWING CALIBRATION
Before calibrating the gate travel, position the gate half-way, check that the maneuvering area is clear of any
obstruction and check that there are mechanical opening and closing stops.
⚠ The mechanical gate-stops are obligatory.
Important! When calibrating, all safety devices will be disabled excluding the one for TOTAL STOP which is active
on on the ESC button.
Select A 3. Press ENTER to confirm.
Select 1 and press ENTER to confirm the travel calibration operation.
.
2
2
2
a
3
2 5
C l
i