Electrical symbols on the device:
Symbol
Meaning
Attention! Magnets might affect the correct functioning of cardiac pacemakers and im-
planted defibrillators. As a user of such medical devices, keep a sufficient distance to
the magnet.
Attention! Please observe documentation!
m
This symbol indicates that the information provided in the operating manual must be
complied with in order to avoid risks.
This symbol on the BENNING VT 2 indicates that the indicator is equipped with protec-
tive insulation (protection class II).
Please observe the operating manual!
This symbol on the BENNING VT 2 means that the BENNING VT 2 complies with the
EU directives.
AC voltage
Earth (voltage to earth)
This symbol shows the orientation of the batteries for inserting them with correct polarity.
2.
Device description (figure A)
1
ProbetipwithLEDindication (red/green)
Grip limit
2
H
LED (red), indication for high sensitivity (detection of electric fields of voltages from approx.
3
12 V AC)
Push-button (blue), for enabling high sensitivity (detection of electric fields of voltages from ap-
4
prox. 12 V AC)
Clip
5
6
Batterycompartmentcover
Test magnet
7
3. Functionaltest
-
Check the phase indicator and magnetic field tester for correct functioning immediately before and
after using it!
-
Test the phase test for correct functioning with a familiar voltage source, e.g. a 230 V socket.
-
Check the correct functioning of the magnetic field test with the integrated test magnet
magnet can be unscrewed from the battery compartment cover
-
Please replace the batteries as soon as the red LED indication
weaker.
-
Do not use the BENNING VT 2, if not all functions are working properly!
-
The BENNING VT 2 has no circuit breaker and is always enabled. A special circuit with low current
consumption extends the battery lifetime and thus ensures that the device is ready for use.
09/ 2020
BENNING VT 2
.
6
1
or the acoustic signal are getting
7
. The test
12