Adjustment of the burning air:
Model
one-hand air slide
SETO
Never close the one-hand air slide control completely during operation (never push the
lever all the way to the right). This should only happen after the flame has gone out com-
pletely.
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with preven-
tive chemicals, furthermore paper and cardboard. For kindling please use wood scrap-
ings or grill starter but never use liquid auxiliaries!
The first kindling
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Warning! Upon the first kindling, smoke and unpleasant smell may be gener-
ated. Always ensure the proper ventilation of the room (by opening windows
and doors), and heat the fireplace at maximum rated heating performance. If
with the first heating the maximum temperature is not reached, the above-
mentioned effects may as well arise later on.
Open the door. If the equipment is hot, you can use insulated gloves. Adjust the pri-
mary air regulator to the Table 1. Put coal lighter or wood wool into the fire grate, fol-
lowed by wood chips. First insert small pieces of wood, and then larger ones, light
them and close the door again. When the wood burns quickly, and leaves sufficient
glowing embers, put additional fuel on the fire. Thereafter, adjust the primary air regu-
lator according to the Table 1 („Adjustment of the burning air"). The first kindling
should be performed "finely" with little fuel only, so that the parts of the fireplace be
adapted to heat. During the first kindling, the generation of smell is normal.
1.3 Putting out of operation
Let the glowing ember burn to ashes and the fire-place get cold.
Empty the furnace chamber and the ash bin.
Close the doors and push the primary air regulator totally to the right.
1.4 Heating instructions
The fireplace should be operated only with closed furnace chamber door. Fireplaces
belonging to type 1 have self-locking furnace chamber doors. These doors may be
opened only for kindling, loading or when cleaning the furnace chamber (otherwise
draught problems may occur with other equipment connected to the same chimney).
Regulator
control
Nominal heating
Starting
performance
3 minutes
OPEN
Table 1
21
Putting out of
½ OPEN
working
CLOSE