22 Troubleshooting Guide
► Inspect the intake screen of the blower and
replace if damaged.
22 Troubleshooting Guide
22.1
Troubleshooting
Always remove the activation key before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on the
blower
3 LEDs flash
red.
Blower does not
start when
switched on.
1 LED
flashes
green.
3 LEDs glow
red.
Blower cuts out
3 LEDs glow
during operation.
red.
Run-time is too
short.
Blower is not
3 LEDs glow
being charged.
red.
23 Specifications
23.1
STIHL BGA 45
Intended for household use.
– Weight: 4.9 lbs. (2.2 kg)
1
Rated capacity calculated pursuant to IEC 61960. Usable energy available to the operator will be
less.
0458-719-8221-B
► Have worn, missing or damaged safety labels
Cause
Remedy
Malfunction in
► Do not attempt to use. The blower has a mal‐
blower.
function and must be checked by a servicing
dealer.
Activation key
► Remove the activation key,
not fully inserted.
► Visually check the electrical contacts of the acti‐
vation key.
► Reinsert the activation key,
Less than 20 %
► Charge the blower,
charge remain‐
ing.
Integrated bat‐
► Remove the activation key,
tery too hot.
► Allow the blower to cool down gradually at ambi‐
ent temperatures of about 50 °F to 68 °F (10 °C
to 20 °C).
Moisture in
► Allow the blower to dry.
blower.
Integrated bat‐
► Remove the activation key,
tery too hot.
► Allow the blower to cool down gradually at ambi‐
ent temperatures of about 50 °F to 68 °F (10 °C
to 20 °C).
Electrical mal‐
► Switch off the blower. Wait at least 5 seconds
function.
and switch it back on,
Blower not fully
► Charge the blower,
charged.
Useful life of
► Have the blower checked by an authorized
integrated bat‐
STIHL servicing dealer.
tery has been
reached or
exceeded.
Integrated bat‐
► Allow the blower to warm up or cool down grad‐
tery too hot / too
ually at ambient temperatures of about 50 °F to
cold.
68 °F (10 °C to 20 °C).
Integrated bat‐
► Allow the blower to warm up or cool down grad‐
tery too hot / too
ually at ambient temperatures of about 50 °F to
cold.
68 °F (10 °C to 20 °C).
► Operate the charger only in enclosed, dry rooms
at ambient temperatures of 32 °F to 104 °F
(0 °C to 40 °C).
– Maximum air velocity: 85 mph (38 m/s)
– Battery technology: Lithium-Ion
– Voltage: 18 V
– Rated capacity in Ah
– Stored energy in Wh
replaced by an authorized STIHL servicing