Sharp PN-655RE Mode D'emploi page 41

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

<Repeater control>
This system has a function to allow setting of multiple monitors connected in a daisy chain using a
single command. This function is called repeater control.
You can use Repeater control function without assigning ID numbers.
[Example]
PC
If monitors are connected as shown above, you can execute a command like "Set all monitors' input
settings to DVI: DIGITAL".
<Repeater control command>
Repeater control is achieved by setting the FOURTH CHARACTER of the parameter to "+".
Example:
VOLM030+
← Sets volume of all monitors to 30.
In repeater control, responses are returned by all the connected monitors.
If you want to determine that a value has been returned by a specifi c set, assign ID numbers to
each monitor in advance.
When some monitors do not return their responses, the probable cause is that the monitors could not
receive the command or command processing is not complete. Do not send a new command.
Example:
(When 4 monitors are connected, and assigned ID numbers: 1 through 4)
VOLM030+
WAIT
OK
001
OK
002
OK
003
OK
004
← If 4 monitors are connected in a chain, reliable operation can be ensured by sending
a new command only after a reply has been returned by 4th (last) monitor.
Repeater control can also be used for reading settings.
Example:
VOLM???+
WAIT
10
001
20
002
Volume settings for all monitors are returned.
30
003
30
004
TIPS
• If repeater control is used during ID designation (IDSL, IDLK), the ID designation is canceled.
Set 1
Set 2
Controlling the Monitor with a PC
Set 3
Set 4
39
E

Publicité

Table des Matières
loading

Table des Matières