<Commands for ID control>
The command examples shown on this page assume the following connection and ID number set up.
PC
IDST......A monitor receiving this command sets its own ID number in the parameter fi eld.
Example: IDST0001
OK
001 ← The ID number of this monitor is set to 1.
TIPS
You can automatically assign ID numbers by using the IDST command with the Repeater control (see
"Repeater control" on page 39).
For example, using the command "IDST001+" automatically sets the ID numbers as shown below.
[Example]
PC
IDST001+ ← ID setting command with repeater control
WAIT
OK
001 ← "OK" response from ID number: 1
OK
002 ← "OK" response from ID number: 2
OK
003 ← "OK" response from ID number: 3
OK
004 ← "OK" response from ID number: 4 (End)
ID number: 1
ID number: 2
ID number: 1
ID number: 2
Controlling the Monitor with a PC
ID number: 3
ID number: 4
ID number: 3
ID number: 4